Page 21

AIR CONDITIONER CARE 

Your new air conditioner is designed to give you many years of dependable service. This section tells you how to 

clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember, 

the cost of this service call is your responsibility. 

__________________________________________ 

Cleaning the Air Filter 

The air filter is removable for easy cleaning. A clean 
filter helps remove dust, lint, and other particles from 
the air and is important for best cooling and operating 
efficiency. Check the filter every 2 weeks to see 
whether it needs cleaning. 
 

NOTE:

 Do not operate the air conditioner without the 

filter in place. 
 
1.  Turn off the air conditioner. 
2.   Remove air filter by pulling down on the indents in 
the top or sides of filter door and sliding air filter up 
and out. Filter door is not removable. 
 

 

 
3.   Use a vacuum cleaner to clean air filter. If air filter 
is very dirty, wash it in warm water with a mild 
detergent. Do not wash air filter in the dishwasher or 
use any chemical cleaners. Air dry filter completely 
before replacing to ensure maximum efficiency. 

Cleaning the Front Panel 

1.  Turn off the air conditioner 
2.  Remove the air filter and clean it separately. See 

Cleaning the Air Filter. 

3.  Wipe the front panel with a soft damp cloth. 
4.  Air dry front panel completely. 

 

 
__________________________________________ 

Repairing Paint Damage of Outside 

Case 

Check once or twice a year for paint damage. This is 
very important, especially in areas near oceans or 
where rust is a problem. If needed, Touchup with a 
good grade enamel paint. 
 

NOTE: 

To reduce paint damage during the winter, 

install a heavy duty cover over the air conditioner 
cabinet. 

__________________________________________

 

Annual Maintenance 

Your air conditioner needs annual maintenance to help 
ensure steady, top performance throughout the year. 
Call your local authorized dealer to schedule an 
annual checkup. The expense of an annual inspection 
is your responsibility. 

 
4.   Replace air filter by sliding filter down into filter 
door and closing filter door. 

 
 
 

Содержание WA418ZRX

Страница 1: ...USER MANUAL 950 0179revA 01 19 2011 FOR MODELS COOLING CAPACITY HEATING CAPACITY WAC418230RX WA418ZRX 18 500 18 200 BTU N A WAC428230RX WA428ZRX 28 500 28 000 BTU N A WAH418230RX WH418ZRX 18 500 18 20...

Страница 2: ...the specific model you have and keep the manual in a safe place for reference The refrigerant used in your portable air conditioner is an environmentally safe and friendly ATTENTION Keep small childre...

Страница 3: ...g screw and Flat washer for window panels 2 ea 3 4 or 1 2 inch Long Hex head Screw 4 Safety Lock 1 1 2 Long Screw and Locknut 4 ea 3 4 Long Flat Head Bolt and Locknut 2 ea Sill Angle Bracket 2 Long He...

Страница 4: ...nstalled without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting parts must be secured to firm wood masonry or metal Follow the dimension in TABLE...

Страница 5: ...cal codes and ordinances Power Supply Cord NOTE Your unit s device may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord c...

Страница 6: ...alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle air conditioner gently Remove Chassis 1 Pull down the front p...

Страница 7: ...he base of the chassis and remove the chassis from the cabinet 9 There may be internal packing protection as shown below This packing material must be removed prior to installation Prepare the Cabinet...

Страница 8: ...does not fall out of the opening during installation or removal The place where the power cord exits the air conditioner should be no more than 6 5 ft 200 cm from a grounded 3 prong outlet Do not blo...

Страница 9: ...way for any changes that may need to be made later during installation 3 Install the support brackets with sill angle brackets attached to the bottom of the cabinet as shown below 4 Tighten all 6 bol...

Страница 10: ...Let the front of the air conditioner hang out approximately 6 DO NOT PUSH ON THE CONTROLS OR FINNED COILS 2 Be sure the chassis is firmly seated in the back of the cabinet 3 Insert all screws removed...

Страница 11: ...he control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The air conditioner can be controlled by the remote or the control panel Cooling On...

Страница 12: ...o Low o Med o High Each time the button is pressed the fan speed mode is shifted If the DRY mode is selected the fan will operate in Low speed Heat Mode Press the Mode button to select heat function P...

Страница 13: ...culation The outside vent should be closed for all other modes Cooling Heating Auto and Dry Fan speed is selectable Auto High Med and Low The Fan only function will display the actual room temperature...

Страница 14: ...y Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop timed program CHECK FILTER FEATURE This feature is a reminder to clean the Air Filter for...

Страница 15: ...ler Replacing Batteries The remote control is powered by two AAA alkaline batteries housed in the back of the remote Do not use rechargeable batteries 1 Remove the cover by pressing down and sliding b...

Страница 16: ...tically shift to COOL Operation with auto fan speed the setting temperature is 80 F And the timer setting program will be cancelled SLEEP button Press this button to activate the Sleep mode This funct...

Страница 17: ...to is selected the temperature is automatically set to 75 F The fan speed will decrease as the room temperature approaches set point Auto operation Ensure the unit is plugged in and power is on 1 Pres...

Страница 18: ...ess this button to activate the SLEEP mode This function is available on COOL HEAT or AUTO mode only and maintains the most comfortable temperature for you In this mode the selected temperature will i...

Страница 19: ...conditioner Timer operation Combined Setting both ON and OFF timers simultaneously AUTO STOP AUTO START On Stop Start operation This feature is useful when you want to stop the air conditioner after y...

Страница 20: ...mode when outside temperature is below 64 F The inside evaporator coil will freeze up and the air conditioner will not operate properly FRESH AIR VENT CONTROL FIG 1 VENT CLOSED FIG 2 VENT OPEN FIG 3 V...

Страница 21: ...the condenser causing a pinging or clicking sound The water droplets help to cool the condenser Air movement from the fan Clicks from the thermostat cycling Vibrations or noise due to poor wall or wi...

Страница 22: ...wash it in warm water with a mild detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the F...

Страница 23: ...it at least 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can...

Страница 24: ...to the outside are open Close all windows and doors The Vent control is set to open on some models Push the Vent control to CLOSED for maximum cooling and or heating The temperature set point or Ther...

Страница 25: ...15P NEMA 6 30P NEMA 6 30P Power Cord Rating amps 15A 25A 25A Power Cord Length Inches 78 3 4 78 3 4 78 3 4 Refrigerant Charge R410a oz 23 28 23 28 38 8 Noise Level dB A 60 5 55 8 53 2 61 58 55 63 59 5...

Страница 26: ...ovides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are exclud...

Отзывы: