2.b.3. Define 1 or 2 delays
You may need to insert 1 or 2 delay characters in the reformatted transmission sequence—
for example to give the host system enough time to process a page jump character before
the MicroBar NX transmits the next character. Delays can also be used in conjunction with
additional control characters to split a single code into two fields.
Delay values are defined in increments of 50 ms using the
Number codes provided at the
end of this manual—if you enter “1”, the delay will be 50 ms, if you enter “2”, the delay will
be 100 ms, to define a delay of 1 second (1000 ms = 50 ms x 20), you must enter the
numbers “2” and “0”.
The maximum delay is 78 x 50 ms = 3.9 seconds.
Procedure
1. Scan a Define Delay code.
2. Scan a number corresponding to the desired 50 ms increment (
Ð
Number codes or
inside back cover of this manual).
3. Scan End Selection.
4. Insert the characters “~” (7Eh) and/or DEL (7Fh) for Delays 1 and 2 when you define the
reformatted transmission sequence (
Ð
2.b.1. Define the reformatting sequence above).
Define Delay 1 For “~” (7Eh)
Define Delay 2 For DEL (7Fh)
Содержание MicroBar NX
Страница 1: ...MB NX RM 00 E 970131 M i c r o B a r N X Reference Manual Preliminary Edition January 1997...
Страница 10: ...Contents x Contents MB NX RM 00 E 970131...
Страница 15: ...ASCII character codes MB NX RM 00 E 970131 5 26h 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh End Selection...
Страница 17: ...ASCII character codes MB NX RM 00 E 970131 7 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h A 41h B 42h C 43h End Selection...
Страница 20: ...ASCII character codes 10 MB NX RM 00 E 970131 X 58h Y 59h Z 5Ah 5Bh 5Ch 5Dh 5Eh _ 5Fh 60h a 61h End Selection...
Страница 124: ...RS 232 input devices 114 MB NX RM 00 E 970131 Data bits Seven Eight Parity Even Odd Mark Space None Stop bits One Two...
Страница 138: ...RS 232 Output to host system 128 MB NX RM 00 E 970131 Baud Rate 9600 75 150 300 600 1200 2400 4800 19200 38400...
Страница 160: ...Symbologies Ames Code 150 MB NX RM 00 E 970131 Symbologies Ames Code Activation Not Active Active...
Страница 177: ...Symbologies EAN 128 MB NX RM 00 E 970131 167 Symbologies EAN 128 Symbologies Code 128 EAN 128...
Страница 181: ...Symbologies Matrix 2 of 5 MB NX RM 00 E 970131 171 Symbologies Matrix 2 of 5 Activation Not Active Active...
Страница 187: ...Symbologies Telepen MB NX RM 00 E 970131 177 Symbologies Telepen Activation Not Active Active Format ASCII Numeric...
Страница 201: ...MB NX RM 00 E 970131 Number codes 1 2 3 4 5 6 7 8 9 0 End Selection...