Data reformatting
38
MB/NX/RM/00/E/970131
2.a. Quick-and-easy reformatting
You must activate data reformatting if you want to transmit reformatted data
(
Ð
1. Activate reformatting and define the input data to be formatted above).
The "quick-and-easy" reformatting option cancels any values entered with the
Compose Input Barcode Data Length function (
Ð
1.3. Compose input barcode data
length).
To cancel the "quick-and-easy" reformatting option, scan the Compose Input
Barcode Data Length code and scan Not Active—Reformat Data
(
Ð
1.1. Activate data reformatting for selected input ports above).
The codes on the next page allow you to extract for transmission 1 or 2 blocks of characters
from the original input string:
1. Scan Activate "Quick-And-Easy" Reformatting.
2. Define the first block:
•
scan Define Start Of Block 1 and scan the ASCII code with the decimal value
corresponding to the position of the first character in Block 1 (
Ð
ASCII character
codes),
•
scan Define End Of Block 1 and scan the ASCII code with the decimal value
corresponding to the position of the last char acter in Block 1.
3. Define the second block if required:
•
scan Define Start Of Block 2 and scan the ASCII code with the decimal value
corresponding to the position of the first character in Block 2,
•
scan Define End Of Block 2 and scan the ASCII code with the decimal value
corresponding to the position of the last character in Block 2.
4. Insert an ASCII string between the two blocks if required:
•
scan Insert ASCII String Between Blocks,
•
scan the codes for the ASCII characters you want to insert (maximum = 120
characters) and scan End Selection to finish.
Example
input data string characters:
1
2
3
4
5
6
input data string format:
SOH
STX
ETX
EOT
ENQ
ACK
to transmit characters 2, 3 and 4:
•
Define Start Of Block 1
STX
•
Define End Of Block 1
EOT
transmitted data string:
2
3
4
Содержание MicroBar NX
Страница 1: ...MB NX RM 00 E 970131 M i c r o B a r N X Reference Manual Preliminary Edition January 1997...
Страница 10: ...Contents x Contents MB NX RM 00 E 970131...
Страница 15: ...ASCII character codes MB NX RM 00 E 970131 5 26h 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh End Selection...
Страница 17: ...ASCII character codes MB NX RM 00 E 970131 7 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h A 41h B 42h C 43h End Selection...
Страница 20: ...ASCII character codes 10 MB NX RM 00 E 970131 X 58h Y 59h Z 5Ah 5Bh 5Ch 5Dh 5Eh _ 5Fh 60h a 61h End Selection...
Страница 124: ...RS 232 input devices 114 MB NX RM 00 E 970131 Data bits Seven Eight Parity Even Odd Mark Space None Stop bits One Two...
Страница 138: ...RS 232 Output to host system 128 MB NX RM 00 E 970131 Baud Rate 9600 75 150 300 600 1200 2400 4800 19200 38400...
Страница 160: ...Symbologies Ames Code 150 MB NX RM 00 E 970131 Symbologies Ames Code Activation Not Active Active...
Страница 177: ...Symbologies EAN 128 MB NX RM 00 E 970131 167 Symbologies EAN 128 Symbologies Code 128 EAN 128...
Страница 181: ...Symbologies Matrix 2 of 5 MB NX RM 00 E 970131 171 Symbologies Matrix 2 of 5 Activation Not Active Active...
Страница 187: ...Symbologies Telepen MB NX RM 00 E 970131 177 Symbologies Telepen Activation Not Active Active Format ASCII Numeric...
Страница 201: ...MB NX RM 00 E 970131 Number codes 1 2 3 4 5 6 7 8 9 0 End Selection...