IM11 RFID Reader Module Integration Guide (Confidential)
21
BRI, Default Attributes, 32 Conducted Tags, READ:
The long, flat CW period
after the inventroy round is caused when the BRI repoprts the tags before
shutting off RF.
Supply Voltage 4.45 V
Conducted Quad Tag, 20 dB Anttenuation
Field Strength
Test A
Test B
Test C
Test D
30 dB
456
57
369
252
27 dB
101
54
299
214
24 dB
88
52
252
193
21 dB
78
49
223
173
18 dB
49
49
204
164
15 dB
49
49
188
162