10
U
U
4 4
TEST FUNCTION
1) Enter [
U
]-[4]-[4]
The test will be performed as programmed.
If the siren test is performed, enter a user code to silence the siren.
U
U
4 5
DISPLAY TEST FUNCTION
1) Enter [
U
]-[4]-[5]
All of the display pixels and LED indicators will flash.
2) Press any key to end test.
U
U
4 6
LIGHT CONTROL FOR X-10 DEVICES
When used in conjunction with an X-10 output device such as an NX507-E, NX508-E, NX534-
E or NX540-E, this menu allows the user to control up to ten X-10 devices from each keypad.
1) Enter [
U
]-[4]-[6]
The LCD Screen will prompt to “Select Light Number 0-
9”.
2) Enter the number of the device to
edit.
The LCD will display the light number on the left. On
the right side of the display it will prompt to turn the
light “On” or “Off”.
3) Press the UP scroll key to turn the
device “ON” or press the DOWN
scroll key to turn the device
“OFF”.
The LCD Screen will return to the prompt to “Select
Light Number 0-9”.
4) Repeat steps 2 and 3 until all of the devices have been programmed as desired.
5) Press [#] to exit this function.
U
U
4 7
HOUSE CODES FOR X-10 DEVICES
When used in conjunction with an X-10 output device such as an NX507-E, NX508-E, NX534-
E or NX540-E, this menu allows the installer to program the specific X-10 unit and house
codes for the ten X-10 devices for this keypad.
1) Enter [
U
]-[4]-[7]
The LCD Screen will prompt to “Please Enter Your
Code”.
2) Enter [program code].
The LCD will display the Light number and Unit Code.
3) Enter the X-10 [unit code]
followed by [
7
].
The LCD Screen will now prompt for the House Code
for the device.
4) Enter the X-10 [house code]
followed by [
7
].
The LCD display will increment to the next Light
number and prompt for its unit code.
5) Repeat steps 3 and 4 until all of the devices have been programmed as desired.
6) Press [#] to exit this function.
U
U
4 9
CHANGE LANGUAGES
1) Enter [
U
]-[4]-[9]
The LCD keypad is now toggled to the second
language. If you enter [
U
]-[4]-[9] again, the keypad will
revert to the first language.