background image

10

U

U

4 4

TEST FUNCTION

1)  Enter [

U

]-[4]-[4]

The test will be performed as programmed.

If the siren test is performed, enter a user code to silence the siren.

U

U

4 5

DISPLAY TEST FUNCTION

1)  Enter [

U

]-[4]-[5]

All of the display pixels and LED indicators will flash.

2) Press any key to end test.

U

U

4 6

LIGHT CONTROL FOR X-10 DEVICES

When used in conjunction with an X-10 output device such as an NX507-E, NX508-E, NX534-
E or NX540-E, this menu allows the user to control up to ten X-10 devices from each keypad.

1)  Enter [

U

]-[4]-[6]

The LCD Screen will prompt to “Select Light Number 0-
9”.

2)  Enter the number of the device to
edit.

The LCD will display the light number on the left. On
the right side of the display it will prompt to turn the
light “On” or “Off”.

3) Press the UP scroll key to turn the

device “ON” or press the DOWN
scroll key to turn the device
“OFF”.

The LCD Screen will return to the prompt to “Select
Light Number 0-9”.

4)  Repeat steps 2 and 3 until all of the devices have been programmed as desired.

5) Press [#] to exit this function.

U

U

4 7

HOUSE CODES FOR X-10 DEVICES

When used in conjunction with an X-10 output device such as an NX507-E, NX508-E, NX534-
E or NX540-E, this menu allows the installer to program the specific X-10 unit and house
codes for the ten X-10 devices for this keypad.

1) Enter [

U

]-[4]-[7]

The LCD Screen will prompt to “Please Enter Your
Code”.

2) Enter [program code].

The LCD will display the Light number and Unit Code.

3) Enter the X-10 [unit code]

followed by [

7

].

The LCD Screen will now prompt for the House Code
for the device.

4) Enter the X-10 [house code]

followed by [

7

].

The LCD display will increment to the next Light
number and prompt for its unit code.

5) Repeat steps 3 and 4 until all of the devices have been programmed as desired.

6) Press [#] to exit this function.

U

U

4 9

CHANGE LANGUAGES

1) Enter [

U

]-[4]-[9]

The LCD keypad is now toggled to the second
language.  If you enter [

U

]-[4]-[9] again, the keypad will

revert to the first language.

Содержание NX1192E

Страница 1: ...MBER AND PARTITION 7 KEYPAD FUNCTIONS 7 7 9 0 READING THE EVENT LOG 7 POSSIBLE LOG MESSAGES 8 7 9 5 SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST 9 7 9 7 SET SYSTEM TIME AND DATE 9 7 0 ADJUST KEYPAD...

Страница 2: ...segment is reached press the key This keypress will not save the changes made to current segment but will exit the location To proceed to the next location press the Police key To return to the previo...

Страница 3: ...4 4 7 5 50 0 n 6 66 6 8 82 2 0 03 3 C 1 19 9 S 3 35 5 8 5 51 1 o 6 67 7 8 83 3 0 04 4 D 2 20 0 T 3 36 6 9 5 52 2 p 6 68 8 8 84 4 0 05 5 E 2 21 1 U 3 37 7 a 5 53 3 q 6 69 9 8 85 5 0 06 6 F 2 22 2 V 3 3...

Страница 4: ...ORATORIO RECIBIDOR TRASERO COCINA EXTERIOR LATERAL SABOTAJE VALLA COMEDOR FACHADA LAVABO SALA VENTANA CONTACTO FUEGO MAGNETICO SALIDA VESTIBULO CRISTAL GARAJE OFICINA SALON ZONA LOADING FACTORY DEFAUL...

Страница 5: ...aller level functions These are samples of the displays that will appear in the Function Menu Each time the U key is pressed the next menu item will be displayed Press the number or key to access the...

Страница 6: ...custom message you must enable Custom Message Lock under the 7 9 3 function For custom messages in the second language NOTE The above 7 9 2 mode must be exited prior to changing languages 1 Enter 7 4...

Страница 7: ...N OPTION Programs special characteristics 1 Display Press 7 For Help 2 Disable LED Extinguish on this keypad 3 On if PIN should be hidden when programming 4 On suppresses beeps when an RF transmission...

Страница 8: ...Reports user number date time and partition of closing Exit Err Exit Error Entry Exit zone was faulted at the instant the exit delay expired Rec Close Recent Close An alarm occurred within 5 minutes...

Страница 9: ...current hour flashing 3 Use the up and down scroll keys to select the proper hour 4 Enter the 7 key to move to the minutes 5 Repeat steps 3 4 until the entire date is set U U 0 ADJUST KEYPAD TONE 1 P...

Страница 10: ...to the prompt to Select Light Number 0 9 4 Repeat steps 2 and 3 until all of the devices have been programmed as desired 5 Press to exit this function U U 4 7 HOUSE CODES FOR X 10 DEVICES When used i...

Страница 11: ...The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Close Rprt Bypass enable Arm Disarm If Prompt 1 Outputs used is answered NO the LCD will displ...

Страница 12: ...eously To set the multi partition mode use the U U 9 3 function and answer YES to the question Master keypad NOTE U 1 followed by a code will temporarily access the Master Mode The keypad will revert...

Страница 13: ...ed Refer to the following table for possible conditions LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE CONDITION Blank Blank Area Not Used or Authorized Dash Dash Area Not Ready Flashing Dash Area Rea...

Страница 14: ...l only work if an individual partition is selected SERVICE DISPLAY The following message will be displayed periodically if the security system requires service 6HUYLFH 5HTXLUHG 7 SH IRU KHOS If you se...

Страница 15: ...an expansion device has been opened SDQVLRQ 5 DPPHG A radio receiver is being jammed SDQVLRQ 7URXEOH An expansion device or keypad is not reporting to the control panel SDQVLRQ 6LUHQ WURXEOH An expans...

Страница 16: ...he end of the wire When connecting more than one keypad to the end of the wire a heavier gauge wire will be required WHEN CONNECTED TO NX8 E WHEN CONNECTED TO NX 320 Length in feet Wire Gauge Wire Gau...

Отзывы: