Chapter 4: Commands for CLI configuration
excessive-restart
Command:
excessive-restart
excessive-restart
Restart backoff algorithm after 16 collisions (No excessive-
restart means discard frame after 16 collisions)
Default:
Discard
Usage Guide:
To enable
Backoff Algorithm
for the specific interface
Example:
To enable
Backoff Algorithm
for the
GigabitEthernet X/X.
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
excessive-restart
exit
Command:
exit
exit
Exit from current mode
Default:
None
Usage Guide:
To exit current mode
Example:
To exit current mode
.
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
exit
Switch (config)#
flowcontrol
Command:
flowcontrol off | on
flowcontrol
Traffic flow control.
off
Disable flow control.
on
Enable flow control.
Default:
Disable
Usage Guide:
To enable
Flow-control
for specific interface
Example:
To enable
Flow-control
for
GigabitEthernet X/X
70
NS3500-24T-4C Managed Switch Command Guide