
Chapter 4: Commands for CLI configuration
spanning-tree bpdu-guard
Command:
spanning-tree bpdu-guard
spanning-tree
Spanning Tree protocol
auto-edge
Auto detects edge status
Default:
Disabled
Usage Guide:
To enable
BPDU Guard
of
CIST Normal Port Configuration
for specific interface
Example:
To enable
BPDU Guard
of
CIST Normal Port Configuration
for
GigabitEthernet
X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
spanning-tree bpdu-guard
spanning-tree edge
Command:
spanning-tree edge
spanning-tree
Spanning Tree protocol
edge
Edge port
Default:
Non-Edge
Usage Guide:
To enable
edge port
of
CIST Normal Port Configuration
for specific interface
Example:
To enable
edge port
of
CIST Normal Port Configuration
for
GigabitEthernet X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
spanning-tree edge
spanning-tree link-type
Command:
spanning-tree link-type auto | point-to-point | shared
spanning-tree
Spanning Tree protocol
link-type
Port link-type
auto
Auto detect
point-to-point
Forced to point-to-point
shared
Forced to Shared
Default:
Auto
Usage Guide:
To configure
point to point mode
of
CIST Normal Port Configuration
for specific
NS3500-24T-4C Managed Switch Command Guide
105