6.15 Thermal Command
Thermal Priority Temperature
Description:
Set or show the temperature at which the ports shall be shut down.
Syntax:
Thermal prio_temp [<prio_list>] [<shut_down_temp>]
Parameters:
<prio_list>
: List of priorities (0-3)
<shut_down_temp>
: Temperature at which ports shall be shut down (0-255 degree C)
Example:
Show thermal priority temperature.
NS3502-8P-2S:/>
Thermal prio_temp
Priority Temp.
--------- -----
0 255 C
1 255 C
2 255 C
3 255 C
Thermal Port Priority
Description:
Set or show the ports priority.
Syntax:
Thermal port_prio [<port_list>] [<prio>]
Parameters:
<port_list>
: Port list or 'all', default: All ports
<prio>
: Priority (0-3)
Default Setting: