background image

 

IFS MCR200-1T-1TW User Guide                                                                              19 

 

Q7

: What is band plan and what’s the effect? 

A8: VDSL2 defines multiple band plans and configuration modes (profiles) 

to allow asymmetric and symmetric services in the same binder (by 

designated frequency bands) for the transmission of upstream and 

downstream signals. User has the ability to select fixed band plan. When 

Symmetric is selected that provides better downstream performance, when 

Asymmetric is selected that provides better upstream performance.

 

 

Содержание IFS MCR200-1T-1TW

Страница 1: ...IFS MCR200 1T 1TW User Guide P N 1072685 REV A ISS 30OCT13 ...

Страница 2: ... N4131 FCC compliance Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed ...

Страница 3: ...ements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Co...

Страница 4: ...ption 2 Key Features 4 Specifications 5 Hardware Description 7 Front Panel 7 The Rear Panel 9 Installation 12 Install Ethernet over VDSL2 Converter 12 Connecting MCR200 1T 1TW 13 Chassis Installation and Rack Mounting MCR200 1T 1TW 15 POWER INFORMATION 16 Troubleshooting 17 FAQ 18 Customer Support 20 ...

Страница 5: ...gital Subscriber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need for rewiring The MCR200 1T 1TW Ethernet Over VDSL2 Converter has a switching architecture with RJ 45 10 100Mbps Ethernet port and one asymmetric or symmetric Ethernet over VDSL port Asymmetric means upstream and downstream rat...

Страница 6: ...or 5 UTP 100Base TX Category 5 5e or 6 UTP Ethernet over VDSL2 Twisted pair telephone wires The two drawings pictures are typical applications diagrams for the Ethernet over VDSL2 Converter Slave device CPE must connect to Master device CO through the telephone wire or coaxial cable It is not allow connecting like Master to Master or Slave to Slave To define the MCR200 1T 1TW to CO or CPE please r...

Страница 7: ...EEE 802 3 IEEE 802 3u and IEEE 802 3x standards DMT Discrete Multi Tone line coding Half Duplex Back Pressure and IEEE 802 3x Full Duplex Pause Frame Flow Control Built in POTS splitter to share voice and data Voice and data communication can be shared on the existing telephone wire simultaneously Support up to 1536 bytes packet size 802 1Q VLAN tag transparent VDSL2 Stand Alone transceiver for si...

Страница 8: ...witch Functionality CO CPE mode select Selectable fast and interleaved mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a Support One Power 3 for RJ 11 VDSL2 LED Indicators 2 for RJ 45 10 100Base TX port Ethernet 10Base T 2 pair UTP Cat 3 4 5 up to 100m 328ft 100Base TX 2 pair UTP Cat 5 5e 6 up to 100m 328f...

Страница 9: ... 20Mbps 1600m 20 15Mbps Power Requirement 5V DC 2A Operating Temperature 0 50ºC Storage Temperature 10 70ºC Operating Humidity 10 to 90 relative humidity non condensing Storage Humidity 10 to 90 relative humidity non condensing Standard Conformance Regulation Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3x Full Duplex Pause frame Flow C...

Страница 10: ... automatically This section describes the hardware features of the Ethernet over VDSL2 Converter For easier control of the converter familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the converter read this chapter carefully Front Panel The units front panel provides a simple ...

Страница 11: ...ate that the VDSL link is at idle status CO Green Light Indicate the VDSL Bridge is running at CO mode CPE Green Light Indicate the VDSL Bridge is running at CPE mode 10 100Base TX Port LED Color Function Light Indicate that the port is Link Up Blink Indicate that the Converter is actively sending or receiving data over that port LNK ACT Green Off Indicate that the port is Link Down Light Indicate...

Страница 12: ...el of the Ethernet over VDSL2 Converter is shown as below Figure 2 MCR200 1T 1TW rear panel MODE DIP Switch The Ethernet over VDSL2 Converter provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with phone line quality or distance of connectivity The following is the summary table of transmission setting bandwidth and distance ...

Страница 13: ... end to end latency less than 1 ms Interleaved mode provides impulse noises protection with a duration less than 250 us Interleaved mode has a maximum end to end latency of 10m sec Band Plan User can switch the Band Plan either Symmetric or Asymmetric by their own When Symmetric is selected that provides better upstream performance when Asymmetric is selected that provides better downstream perfor...

Страница 14: ...uired device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your Ethernet Over VDSL2 Converter from being damaged by unregulated surge or current to...

Страница 15: ...telephone and the other one for network link connection Depending on the quality of telephone line the maximum distance of one VDSL segment is 1 6km 6561ft with AWG 24 telephone wires The MC251 4P 1CXT and MC250 4T 1CXT can utilize standard telephone POTS type cable for transmission of Ethernet IP data It is not designed for transmitting Ethernet data on a PBX system or public switch telephone net...

Страница 16: ...1T 1TW to be CO or CPE mode from the DIP switch at the rear panel 2 Power on the MCR200 1T 1TW by connecting its power source 3 Power LED will illuminate Connect VDSL line from another VDSL device to VDSL port of 4 The MCR200 1T 1TW 5 LNK LED will blink to illuminate 6 Connect telephone to the PHONE port 7 Connect Ethernet port to PC Network Interface Card NIC via regular Cat 5 5e or 6 cable Figur...

Страница 17: ...0 1T 1TW by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the MCR200 1T 1TW LNK LED will illuminate 5 Connect telephone to the PHONE port 6 MCR200 1T 1TW Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 5e or 6 cables Figure 3 5 Connecting Multiple PCs to an Ethernet LAN Please refer to your Ethern...

Страница 18: ...of the converter chassis Figure 3 8 Insert a VDSL2 converter into an available slot Step 3 Attach a rack mount bracket to each side of the Converter Chassis with supplied screws attached to the package Step 4 After the brackets are attached to the Converter Chassis use suitable screws to securely attach the brackets to the rack Step 5 Proceed with the steps 4 and steps 5 of session Stand alone Ins...

Страница 19: ... have encountered the issue to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when your MCR200 1T 1TW is installed into a Media Chassis 2 5mm DC Receptacle 2 5mm 5V for each slot For Media Chassis DC receptacle is 2 5mm wide that conforms to and matches the VDSL2 Converter 2 5mm DC jack s central post Do not install any imprope...

Страница 20: ...ect to each other to make it work SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector to connect to the port 2 If your device like LAN card supports to Auto Negotiation please try to modify at a fixed speed of your device by manually 3 Check the converter and the connected device s power are ON or OFF 4 ...

Страница 21: ...he MCR200 1T 1TW is up to 100Mbps 55Mbps Q5 Is the MCR200 1T 1CX compatible with the MCR200 1T 1TW A5 Currently NO Although the MCR200 1T 1CX profile 12a and the MCR200 1T 1TW profile 17a are base on ITU T G 993 2 VDSL2 but with different Profiles so far they are not compatible with each other Q6 What is SNR and what s the effect A7 In analog and digital communications Signal to Noise Ratio often ...

Страница 22: ...files to allow asymmetric and symmetric services in the same binder by designated frequency bands for the transmission of upstream and downstream signals User has the ability to select fixed band plan When Symmetric is selected that provides better downstream performance when Asymmetric is selected that provides better upstream performance ...

Страница 23: ...terlogix com techsupport interlogix com rma fs utc com UTC Fire Security 8985 Town Center Parkway Bradenton FL 34202 5129 Australia 61 3 9239 1200 Customer Service 1300 361 479 customerservice interlogix com au Technical Support 1300 780 904 security tech support interlogix com au Head Office Level 1 271 273 Wellington Road Mulgrave Victoria 3170 Latin America Latam interlogix com 1 561 998 6114 E...

Отзывы: