programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 18 - Main Server Port
Default = 0080; Range = 4-digit numeric, 0000-9999
This option stores the TCP port that is used to communicate
with the permesisconnect.com server.
Remote Option 19 - Ping Server IP Address
Default = 198.204.22.185; Range = 12-digit, 4 octet
This option stores the ping server IP Address associated with
premisesconnect.com. If left at the default the Ethernet
Interface module uses premisesconnect.com for the ping
server.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 20 - Ping Server Port
Default = 0080; Range = 4-digit numeric, 0000-9999
This option stores the TCP port used to communicate with the
ping server associated with premisesconnect.com.
Remote Option 21 - Ping Page Base Name
Default = ping1; Range = 10-character alphanumeric
This option stores the base portion of the address of the ping
web page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 22 - Main Server Page Base Name
Default = simon3; Range = 10-character alphanumeric
This option stores the base portion of the address of the main
web page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 23 - Registration Page Base Name
Default = gwreg; Range = 10-character alphanumeric
This option stores the base portion of the address of the
registration page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 24 - Ping Page Extension
Default = aspx; Range = 5-character alphanumeric
This option stores the extension of the address of the ping web
page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 25 - Main Server Page Extension
Default = aspx; Range = 5-character alphanumeric
This option stores the extension of the address of the main
server web page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 26 - Registration Page Extension
Default = aspx; Range = 5-character alphanumeric
This option stores the extension of the address of the
registration web page on premisesconnect.com.
To enter letters, press 9 then the M button. The panel
announces the letter A. Continue pressing the M button
to progress through the alphabet.
Remote Option 27- Receiver 1 IP Address
Default = 000.000.000.000; Range = 12-digit, 4 octet
When the Ethernet Interface module has a TCP/IP connection
to a OH2000 network receiver available this option should be
programmed with the IP address for the primary receiver.
Leave this option set to 000.000.000.000 to disable
communication to the primary network receiver.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 28 - Receiver 1 Number
Default = 0001; Range = 4-digit, 0000-9999
This option sets the Receiver Number the primary TCP/IP
central station receiver should use for this account.
Ethernet Interface Installation Instructions
9