5. Press Done to reset the module.
Resetting the module does not clear its memory.
Remote Option 7- Static Module IP Address
Default = 192.168.000.049; Range = 12-digit, 4 octet
When DHCP is Off, this option sets the IP address of the
Ethernet Interface module. This option is not used if DHCP is
On.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 8- Static Router IP Address
Default = 192.168.000.001; Range = 12-digit, 4 octets
When DHCP is Off, this option sets the router IP address used
by the Ethernet Interface module. This option is not used if
DHCP is On.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 9- Static Subnet Mask
Default = 255.255.255.000; Range = 12-digit, 4 octets
When DHCP is Off, this option sets the subnet mask used by
the Ethernet Interface module. This option is not used if DHCP
is On.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 10- Current Module IP Address
Default = Dynamic; Range = 12-digit numeric
This option stores the current IP address of the Ethernet
Interface module. This option cannot be programmed and is for
review only.
Remote Option 11- Current Router IP Address
Default = Dynamic; Range = 12-digit numeric
This option stores the current IP address of the router through
which the Ethernet Interface module is connected. This option
cannot be programmed and is for review only.
Remote Option 12- Current Subnet Mask
Default = Dynamic; Range = 12-digit numeric
This option stores the current Subnet Mask of the Ethernet
Interface module. This option cannot be programmed and is for
review only.
Remote Option 13- MAC Address
Default = Dynamic; Range = 12-digit hexidecimal
This option stores the current MAC address of the Ethernet
Interface Module. This option cannot be programmed and is for
review only.
Remote Option 14- Proxy Server IP Address
Default = 000.000.000.000; Range = 12-digit, 4 octet
When a proxy server is used to communicate with the Internet,
enter the IP address of the proxy server in this option. Leave
this option set to 000.000.000.000 when not using a proxy
server.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
programmed at the panel as “010.001.008.100”. It is not
necessary to enter the periods.
Remote Option 15 - Proxy Server Port
Default = 0080; Range = 4-digit numeric, 0000-9999
Enter the TCP port the proxy server uses to communicate with
the Ethernet Interface module.
Remote Option 16 - Clear Module Memory Command
Default = N/A; Range = N/A
Used to clear the Ethernet Interface module memory.
1. Press
Add
2. Press Option #
3. Press
Test
4. Press Option # until panel says “Remote Option 16...”
5. Press Done to clear the Ethernet Interface module
memory.
This sets all options to their factory default settings.
Remote Option 17 - Main Server IP Address
Default = 198.204.22.184; Range = 12-digit, 4 octet
This option stores the IP address of the server on which
premisesconnect.com is located. This option is normally set at
the factory.
Note
: When programming an IP address, 3 digits must be
used for each octet. An address of 10.1.8.100 would be
8