background image

Interflex Datensysteme GmbH   

10/13 

 

5  Synchronizing the Reader and Setting the LED Color 

Structural conditions may make it necessary to fine-tune or readjust the reader. To do so, the adjustment set 

with the order number 75-99-0004 is required. 

  In order to achieve the best result, perform fine tuning at the location of use while the back panel is 

attached. 

 

 

Anti-tamper switch 

Screw for adjusting the reader 

Terminal clamps 

2-pin DIP switch for setting the LEDs 

 

  Switch on the power supply. 
  Turn the adjusting screw (3) until the field indicator reaches maximum. 

Setting the LEDs 

Use the DIP switch (4) to set the LEDs according to the color of the display. The switch setting is usually 

preset (factory default). 

  Check the setting of the DIP switches according to the table specifications. 

 

Design 

Switch 1/design color white 

Switch 2/design color blue 

Glass, white 

OFF 

ON 

Glass, black 

ON 

ON 

 

  Further settings are reserved for other designs. 

 

6  Device Settings 

6.1  Setting the hardware address 

  Use the address switch to set the hardware address of the device. 

 

Switch 

Address 1 

OFF 

OFF 

OFF 

OFF (not required if connected to a master terminal) 

Address 2 

OFF 

OFF 

OFF 

ON 

Address 3 

OFF 

OFF 

ON 

OFF 

Address 4 

OFF 

OFF 

ON 

ON 

Address 5 

OFF 

ON 

OFF 

OFF 

Address 6 

OFF 

ON 

OFF 

ON 

Address 7 

OFF 

ON 

ON 

OFF 

Address 8 

OFF 

ON 

ON 

ON 

 

Содержание IF-80x

Страница 1: ...ocumentation are protected by commercial and patent laws 1 3 Shielded cables To ensure malfunction free operation we recommend the use of shielded bus cables Operation is also possible with unshielded...

Страница 2: ...ices They are generally connected to a master terminal access manager or terminal controller via an RS485 data cable These terminals are designed for controlling the access of persons who identify the...

Страница 3: ...appliance case 2 Alternative mounting hole for wall mounted cable inserted from the bottom 6 Mounting holes for US standard 3 Cable gland 7 Hole for adjusting the reader 4 Horizontal mounting option...

Страница 4: ...ce Use only the original screws and do not use any washers Screws placed too high can cause collisions with other components and damage the device Ensure short cable routing Cable loops can damage the...

Страница 5: ...ire is wrapped around the insulation 8 The blue wire and the PE wire from the I O controller board are connected to terminal 8 on the terminal strip 7 The blue wire is connected to the strain relief 9...

Страница 6: ...rminal 3 Patch cable from computer to switch or hub 6 RS 485 data cable from controller master terminal to I O controller board Please refer to the table Function of Cables and Cable Types for detaile...

Страница 7: ...e wire under a nut of the strain relief 12 Now connect all of the cables coming from the I O controller board to the terminal strip of the terminal Then connect the blue wire from the back panel of th...

Страница 8: ...cuit example Power supply 7 Address switch on the I O controller board 4 Circuit example RS485 connection The spur line may not be longer than max 100 m Bridges Br 1 When one I O controller board is u...

Страница 9: ...door terminal is usually very long we recommend connecting the power supply and the relay contact with one cable pair each 4 5 Connecting a further I O controller board If more than two inputs or more...

Страница 10: ...maximum Setting the LEDs Use the DIP switch 4 to set the LEDs according to the color of the display The switch setting is usually preset factory default Check the setting of the DIP switches accordin...

Страница 11: ...the terminal number Example cfg address 8 has been set Enter this command etp address cx The controller responds with TC ET 8 Then the command 34xxyy is sent directly to the terminal Example Address...

Страница 12: ...board Br 2 Bridge 2 is used to set the switching contacts of the NO NC relay Br 3 Instead of bridge 3 an anti tamper switch can be connected See also Wiring Overview 8 7 Initial Operation Once you hav...

Страница 13: ...condensing Protection category III Degree of protection IP54 provided that the cables are installed according to instructions The lower cable inlet must be masked using the included adhesive strip Dim...

Отзывы: