background image

Interflex Datensysteme GmbH   

11/13 

 

6.2  Setting the address without an I/O controller board 

If an I/O controller board without an address switch is used, you can set the address of the IF-80x Outdoor 

terminal via the RS-485 data cable. 
Once the terminal is connected to the controller, it responds with host address 8. 
Set the address of the terminal with a Telnet connection via the controller as follows: 

  Set up the connection to the controller with Telnet. 
  Use the command 

cfg

 to retrieve the terminal number. 

Example:

 

cfg

 -> address 8 has been set. 

 

  Enter this command: 

etp <address> -cx

 

 

The controller responds with TC-->ET(8)= 
Then, the command 34xxyy is sent directly to the terminal. 

Example: Address 1:

 

xx = New address A (uppercase) corresponds to 41(Hex) 
xx = New address a (lowercase) corresponds to 61(Hex) 
The command for setting address 1 is: 344161   

Correspondingly for address 2: 344262 (see table). 
Via a warm boot (command 55), the terminal then recognizes its new address: 

 

After approximately 10 seconds, the terminal is ready for operation and can be checked via the cfg 

command: 

 

  Make sure that an address is not used twice. The address must be within the address range of the 

controller (IF-4070). 

Содержание IF-80x

Страница 1: ...ocumentation are protected by commercial and patent laws 1 3 Shielded cables To ensure malfunction free operation we recommend the use of shielded bus cables Operation is also possible with unshielded...

Страница 2: ...ices They are generally connected to a master terminal access manager or terminal controller via an RS485 data cable These terminals are designed for controlling the access of persons who identify the...

Страница 3: ...appliance case 2 Alternative mounting hole for wall mounted cable inserted from the bottom 6 Mounting holes for US standard 3 Cable gland 7 Hole for adjusting the reader 4 Horizontal mounting option...

Страница 4: ...ce Use only the original screws and do not use any washers Screws placed too high can cause collisions with other components and damage the device Ensure short cable routing Cable loops can damage the...

Страница 5: ...ire is wrapped around the insulation 8 The blue wire and the PE wire from the I O controller board are connected to terminal 8 on the terminal strip 7 The blue wire is connected to the strain relief 9...

Страница 6: ...rminal 3 Patch cable from computer to switch or hub 6 RS 485 data cable from controller master terminal to I O controller board Please refer to the table Function of Cables and Cable Types for detaile...

Страница 7: ...e wire under a nut of the strain relief 12 Now connect all of the cables coming from the I O controller board to the terminal strip of the terminal Then connect the blue wire from the back panel of th...

Страница 8: ...cuit example Power supply 7 Address switch on the I O controller board 4 Circuit example RS485 connection The spur line may not be longer than max 100 m Bridges Br 1 When one I O controller board is u...

Страница 9: ...door terminal is usually very long we recommend connecting the power supply and the relay contact with one cable pair each 4 5 Connecting a further I O controller board If more than two inputs or more...

Страница 10: ...maximum Setting the LEDs Use the DIP switch 4 to set the LEDs according to the color of the display The switch setting is usually preset factory default Check the setting of the DIP switches accordin...

Страница 11: ...the terminal number Example cfg address 8 has been set Enter this command etp address cx The controller responds with TC ET 8 Then the command 34xxyy is sent directly to the terminal Example Address...

Страница 12: ...board Br 2 Bridge 2 is used to set the switching contacts of the NO NC relay Br 3 Instead of bridge 3 an anti tamper switch can be connected See also Wiring Overview 8 7 Initial Operation Once you hav...

Страница 13: ...condensing Protection category III Degree of protection IP54 provided that the cables are installed according to instructions The lower cable inlet must be masked using the included adhesive strip Dim...