.3  General Hazards in the Event of non-compliance with the Safety

Instructions

 

The device 

is in compliance

 with current safety requirements. Residual dangers can emanate from 

the  device if it is improperly used and operated by untrained personnel. Any person entrusted with 

the

 

installation,  operation,  maintenance  and  repair  of  the  device  must  read  and  understand  the 

operating  instructions and, in particular, the safety instructions.

Incorrect use (e. g. by untrained personnel) may result in residual hazards. The operating instructions  

must be read and understood by all persons involved in the installation, commissioning, maintenance, 

repair, operation and dismantling of the device. The device must not be used if da

mage is visible.

 

1

.4  Residual Hazards

The system planner, equipment supplier and operator must plan, implement and be responsible for

 

the safety of the equipment. Other hazards must be minimized. The residual dangers of 

measurement technology must be pointed out and human error must be taken into account. The 

design of the 

system must be suitable for avoiding hazards - a hazard analysis must be carried out 

for the system.

  

2

  Safety and Warning Notices

2

.1  Symbols

Warning

: There is a risk of injury to persons. Damage to the machine is possible. The  

accident prevention regulations of the employer‘s liability insurance association must  

be observed. 

Note

: Important points to be observed. A note that indicates a possible danger of da- 

 

 

 

mage to the product, process, person or the environment.

Additional information or reference to other important detailed information.

Interface Inc.

Page (3)

Содержание SI-USB4

Страница 1: ...Installation User Manual SI USB4 SI USB4 Installation User Manual...

Страница 2: ...1 Symbols 3 2 2 Health Protection and Safety 4 2 3 Conversions and Changes 4 3 Preamble 4 3 1 Product Description 4 3 2 Safe and correct Use 5 4 Housing Connection 6 5 1 Front 6 5 2 Back 6 5 Pin Assig...

Страница 3: ...chnical implementation are prerequisites for the safe installation commissioning safe operation and maintenance of Interface devices All measures must only be carried out by qualified personnel All pe...

Страница 4: ...be observed Supply and signal lines must be installed in such a way that they do not interfere with the function of the Interface device such as inductive or capacitive interferences Notes on Malfunct...

Страница 5: ...not be used if damage is visible 1 4 Residual Hazards The system planner equipment supplier and operator must plan implement and be responsible for the safety of the equipment Other hazards must be mi...

Страница 6: ...or damages resulting therefrom Repairs and modifications are prohibited 3 Preamble 3 1 Product Description The SI USB4 is a measuring amplifier with up to four independent input channels Each input ch...

Страница 7: ...related scaling and adjustment data Display for the presentation of measured data actual value tare value minimum value and maximum value Presentation of the measured data in a diagram Storage of meas...

Страница 8: ...ossible at sensor con nection 1 and or sensor connection 4 4 2 Back In addition to the serial number in the first field the sensors and their associated connections are listed here in the second field...

Страница 9: ...0 10mA 12 8mA 0 5V PT100 5VTTL Pin 1 Ground supply 4V and 12V 0V 1 Wire GND Top view Pin 2 12V active supply 12VDC Pin 3 NC Pin 4 Signal angle A 5V TTL Pin 5 Signal angle B 5V TTL Pin 6 Ground 0V Pin...

Страница 10: ...USB4 Output 0 25000 Digits 6 2 PT100 Industrial Temperature Sensor with Four Wire Measuring Connect the Signal and Signal wires as close as possible to the PT100 30 1 m R 5000 ILoad 170 mA 5V Referenc...

Страница 11: ...rrent than available for the SI USB4 this sensor cannot be used to gether with the SI USB4 Power supply not connected Connect power supply Supply voltage is shortened Fix the short circuit Output sign...

Страница 12: ...its Supply voltage of mains adapter 100 240VAC Output of mains adapter 24VDC 1 25 A Supply voltage SI USB4 10 30VDC 880 mA Sensor Side Sensor supply 4V 20 mA 12V 80 mA 5V 170 mA 4V 20 mA 5V 85 mA Cabl...

Страница 13: ...ng charges freight insurance and proper packaging to prevent breakage in transit Interface warranty does not apply to defects resulting from action of the buyer such as mishandling improper interfacin...

Отзывы: