What is Intended Use, What is not intended Use

A  device from 

Interface

 is used for display, processing and control of processes. It  must not be used 

as the sole means of averting dangerous conditions on machines and systems.

 

Machines and 

systems must be designed in such a way that faulty states cannot lead to a dangerous  situation for 

the operating personnel (e. g. through independent limit value-switches or mechanical  interlocks). 

In particular, it must be ensured that a the malfunction or failure 

of the device 

does not  lead to 

damage to property or loss that c

ould en

danger people. It is also important to 

ensure that safety 

precautions 

are not being 

circumvented for the safety of a plant. Emergen

cy stop devices must 

remain effective at all times.

Installation Instructions

Devices  from 

Interface

  must  be  installed  and  connected  in  compliance  with  the   relevant DIN and 

VDE  standards.  They  must  be  installed  in  such  a  way  that  unintentional  operation  

is  sufficiently 

excluded. 

T

o prevent an interruption of the supply and signal lines from leading to an 

 undefined

 or 

dangerous state, appropriate hardware and software safety precautions must be 

ob

served. Supply 

and signal lines must be installed in such a way that they do not interfere with the function of the 

Interface device (such as inductive or capacitive interferences).

Notes on Malfunctions, Maintenance and Repair

The  device  do

es

  not  contain  any  parts  that

 

can  be  serviced  by  the  user.  Repairs  may  only   be 

carried out by 

Interface

. If it can be assumed that safe operation of the device is  no  longer  possible, 

it  must  be  put  out  of  operation  immediately  and  secured  against  unintentional   operation.  This 

applies in particular if:

The device is visibly damaged

The device is no longer functional

Parts of the appliance are loose

The connecting lines are visibly damaged

In addition, we would like to point out that all obligations of 

Interface

 arise exclusively from the

respective purchase contract in which the warranty is conclusively stated.

1

.2  Intended Use

Devices from 

Interface

 are to be used exclusively for measuring tasks and the directly associated 

control tasks. Any use beyond this is considered to be improper. 

Legal and safety regulations must 

be observed during measurement. The instrument is not a safety component in the sense of its 

intended use and must be transported and stored properly. Installation and commissioning, as well 

as operation and disassembly must be carried out professionally.

Interface Inc.

Page (2)

Содержание SI-USB4

Страница 1: ...Installation User Manual SI USB4 SI USB4 Installation User Manual...

Страница 2: ...1 Symbols 3 2 2 Health Protection and Safety 4 2 3 Conversions and Changes 4 3 Preamble 4 3 1 Product Description 4 3 2 Safe and correct Use 5 4 Housing Connection 6 5 1 Front 6 5 2 Back 6 5 Pin Assig...

Страница 3: ...chnical implementation are prerequisites for the safe installation commissioning safe operation and maintenance of Interface devices All measures must only be carried out by qualified personnel All pe...

Страница 4: ...be observed Supply and signal lines must be installed in such a way that they do not interfere with the function of the Interface device such as inductive or capacitive interferences Notes on Malfunct...

Страница 5: ...not be used if damage is visible 1 4 Residual Hazards The system planner equipment supplier and operator must plan implement and be responsible for the safety of the equipment Other hazards must be mi...

Страница 6: ...or damages resulting therefrom Repairs and modifications are prohibited 3 Preamble 3 1 Product Description The SI USB4 is a measuring amplifier with up to four independent input channels Each input ch...

Страница 7: ...related scaling and adjustment data Display for the presentation of measured data actual value tare value minimum value and maximum value Presentation of the measured data in a diagram Storage of meas...

Страница 8: ...ossible at sensor con nection 1 and or sensor connection 4 4 2 Back In addition to the serial number in the first field the sensors and their associated connections are listed here in the second field...

Страница 9: ...0 10mA 12 8mA 0 5V PT100 5VTTL Pin 1 Ground supply 4V and 12V 0V 1 Wire GND Top view Pin 2 12V active supply 12VDC Pin 3 NC Pin 4 Signal angle A 5V TTL Pin 5 Signal angle B 5V TTL Pin 6 Ground 0V Pin...

Страница 10: ...USB4 Output 0 25000 Digits 6 2 PT100 Industrial Temperature Sensor with Four Wire Measuring Connect the Signal and Signal wires as close as possible to the PT100 30 1 m R 5000 ILoad 170 mA 5V Referenc...

Страница 11: ...rrent than available for the SI USB4 this sensor cannot be used to gether with the SI USB4 Power supply not connected Connect power supply Supply voltage is shortened Fix the short circuit Output sign...

Страница 12: ...its Supply voltage of mains adapter 100 240VAC Output of mains adapter 24VDC 1 25 A Supply voltage SI USB4 10 30VDC 880 mA Sensor Side Sensor supply 4V 20 mA 12V 80 mA 5V 170 mA 4V 20 mA 5V 85 mA Cabl...

Страница 13: ...ng charges freight insurance and proper packaging to prevent breakage in transit Interface warranty does not apply to defects resulting from action of the buyer such as mishandling improper interfacin...

Отзывы: