background image

 

 

Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 

www.interfaceforce.com

 ● Email: 

[email protected]

 ● ORDER TOLL-FREE 800.947.5598

 

16 

Show Min Max 

By default the chart auto scales as the data moves across it which means that if a transient occurs the chart will 
rescale but once that transient leaves the viewport the chart will auto-scale again based on the lower magnitude 
data that follows. By selecting this feature the chart scaling will be locked to the minimum and maximum values 
detected while the feature is active. 

Also, when activated, the values of the detected min and max along with the difference between the two are 
displayed in the lower right of the window in the Help pane. 

 

To deactivate the Min Max function set the switch to off. Next time it is switched on the min and max values will be 
reset. 

 

Capture Viewed 

Although you are always able to Capture All data recorded so far, the Capture Viewed button gives you the options 
of capturing only the data currently visible on the chart. Sometimes the data you are interested in can be recognised 
from the chart so this avoids having to capture and review all of the recorded data which may be up to 30 minutes 
worth. 

Copy Chart Image 

This feature is available by right-clicking on the chart and copies the chart image to the clipboard enabling pasting 
into other applications. 

 

Содержание DIG-USB-F

Страница 1: ...Model DIG USB F Fast Digital USB Output Module Issue 15 296 Revision A User Manual www interfaceforce com...

Страница 2: ...dware Wizard 5 Using the Software 6 Home Page 7 Information Page 8 Save and Restore Page 10 Lock Page 11 Calibration Page 12 System Zero 13 Auto Calibration 13 Table Calibration 14 Engineering Units 1...

Страница 3: ...ents After the DIG USB F software and hardware setup is complete data can start to be extracted acquired and manipulated by software removing the need for amplifiers filters and or multimeters Streaml...

Страница 4: ...ors Two point auto calibration by application of known weight Two point table calibration from load cell calibration certificate Setting System Zero Engineering unit selection Save module settings inc...

Страница 5: ...installation file downloaded from the Interface Inc website www interfaceforce com The software installer AutoRun process will start momentarily If the CD or USB storage media AutoRun process does no...

Страница 6: ...ifferent dialog windows but the dialogs shown below should allow you make the correct choices regardless of operating system Note that the DIG USB F shares the drivers with the DIG USB DSC range of mo...

Страница 7: ...ly detected and the Information page is displayed If the DIG USB F module is not detected the Home page will be displayed either wait until the DIG USB F module is connected or press the Detect button...

Страница 8: ...Phone 480 948 5555 www interfaceforce com Email contact interfaceforce com ORDER TOLL FREE 800 947 5598 7 Home Page Click the Home icon to manually connect a module Click the Detect button after the...

Страница 9: ...while on the Information page The Information page shows a large reading display box selection options for reading output and module information The Information page will also indicate error conditio...

Страница 10: ...icking the Select display format button allows you to select a new format for the displayed value By using this you can hide unwanted decimal places Click the desired display format in the list Error...

Страница 11: ...is recorded while on this page The Save Restore page allows a user to save and restore configuration settings for different modules Clicking the Save button opens Windows save file dialog box and all...

Страница 12: ...ace Inc to aid in Passcode recovery if the Passcode is forgotten Calibration Page Enables the user to either Allow or Lock access to the Calibration Page setting this function to Lock limits access to...

Страница 13: ...methods perform system zero and set calibrated engineering units mV V Input Shows the actual mV V input as measured by the module Calibrated Value Shows the calibrated value in the engineering units...

Страница 14: ...om a measured value A value can be manually entered or automatically filled in by clicking the Zero Now button this gives a zero reading based on the current input Disable the Zero Now feature on the...

Страница 15: ...the certificate or convert the certificate weight to any other engineering unit of your choice click the Calibrate button and the calibration is complete Engineering Units The Engineering Units tab al...

Страница 16: ...a for up to 30 minutes and provides the user the ability to perform transient filtering and display max min values View Window Use the Viewing Window slide bar to select between 1 and 30 seconds of da...

Страница 17: ...values of the detected min and max along with the difference between the two are displayed in the lower right of the window in the Help pane To deactivate the Min Max function set the switch to off N...

Страница 18: ...ick the icon to access the Review page features The Review page allows the user to examine all captured data discard unwanted data view cursors and load and save data The chart displays all data inclu...

Страница 19: ...you to zoom in and out of the data as well as pan through the data You can change the viewed data by dragging the highlighted portion as follows Expand or contract the highlighted area by clicking th...

Страница 20: ...the time difference between the two cursors Plus the frequency if you had placed the cursors on two adjacent features in a wave based signal and the value difference Cursors are cleared once the navig...

Страница 21: ...licking on the chart and copies the chart image to the clipboard enabling pasting into other applications Scope Page Click the icon to access the Scope page features This page offers a simple oscillos...

Страница 22: ...which the left hand side of the scope starts to draw the waveform Trigger Turns the trigger on or off Edge Falling Normally the trigger is set to detect a rising edge Turn Edge Falling to On to detect...

Страница 23: ...end of the purple navigation bar to zoom into the frequency range of interest The purple bar can be panned as well as resized Peak Hold When activated this simply holds the maximum for each frequency...

Страница 24: ...force com ORDER TOLL FREE 800 947 5598 23 Chapter 3 Installation This chapter gives detailed information on integrating the DIG USB F into a production system including mounting protection adjustments...

Страница 25: ...1 Gain Stability with Time 0 0030 of FS 2 Non Linearity before Linearization 0 0005 0 0025 of FS Internal Resolution 16 Million Counts divs Resolution 4 8kHz readings Noise stable over 1s 8 192 Count...

Страница 26: ...SA Phone 480 948 5555 www interfaceforce com Email contact interfaceforce com ORDER TOLL FREE 800 947 5598 25 Dimensions Mounting The following diagrams show the case dimensions and mounting holes and...

Страница 27: ...l part DSCUSB DIN consists of a pair of screws and two DIN rail clips Remove the two screws on the rear of the DIG USB F case and replace with the longer screws from the DIG USB F DIN kit These longer...

Страница 28: ...socket can accept a mating plug that has screw retention functionality The micro USB socket does not have any form of cable retention and this must be taken into account if mounting the DIG USB F to...

Страница 29: ...ight insurance and proper packaging to prevent breakage in transit Interface warranty does not apply to defects resulting from action of the buyer such as mishandling improper interfacing operation ou...

Отзывы: