Operating Instructions
4/8-indent crimping tool CO.236.00
Rev.: 2015-10-16
9 / 12
EN
10 E1 message after calibration or recalibration
If the crimper display shows an E1 message after several calibration or recalibration attempts
(the message will be shown in sequence at first, then permanently as E1), then the dies in
your four-indent crimper are so worn that the wear can no longer be compensated for. Send
your crimper to the manufacturer or an authorised repair shop for repairs.
11 Monitoring wear – General
Any tool is subject to a certain amount of wear, even if used properly. Press the MODE button
(6) for ten seconds – range: 8 to 15s – for your crimper's current condition with numerical
data on the crimper display (5).
The following information will be shown in sequence:
· Serial number (eight digits in sequence)
· Remaining lifetime in percent (remaining service life)
· Reference value – lower setting as specified by the manufacturer
· Number of calibrations so far
12 Troubleshooting and remedy
Display Cause
Solutiont
E1
The crimper was not turned down to
its lower (reference) setting using the
adjustment wheel after changing the
battery.
Repeat the procedure. (See 9,
Calibration after a battery change)
NOTE
An E... error message instead of the default setting of 2.0 mm shown in the
display after calibration means that the lower reference value has not been set
correctly. You will need to repeat calibration.