background image

ProfessIonAl PoWer AMPlIfIer

21

DsA-500Q/2000Q

In loCK PAnel, you can loCK or UnloCK the functions controlled from the front of the device.
If you set the device to loCK, the system will redirect you to the initial oleD screen, and you will not be able
to  use  the  buttons  at  the  front  of  the  device.  To  UnloCK  the  device,  press  down  the  seleCT/enTer
(enCoDer) dial at the front, then type the loCK/UnloCK password. The initial password is 0000.

6. 3 DEVICE NAME

DeVICe nAMe displays the name of the device. You can change the DeVICe nAMe from the PC program.
Please refer to the PC program manual for detailed instructions. You can download the PC program manual
from our company’s official website (www.inter-m.net).

6. 4 FACTORY RESET

In fACTorY reseT, you can initialize the device to its factory settings.
If  you  press  CAnCel  or  the  esC  button  at  the  front  of  the  device,  you  will  be  redirected  to  the  previous
screen.

6. 5 VERSION

In VersIon, you can check the firmware version, DAnTe neTWorK version of the current device.
The screen will display the firmware version of the device at all times. However, it will display the DAnTe
neTWorK version only when DAnTe is connected to the device.

 

 

 

 

 

 

 

[ DEVICE NAME ]

 

DSA-SERIES 

 

 

 

 

 

 

 

 

 

 

       

 

 

 

 

 

 

 

 

[ FACTORY RESET ]

 

> CANCLE

FACTORY RESET

 

 

 

 

 

 

 

 

 

       

 

 

 

 

 

 

 

 

 

[ DEVICE VERSION ]

 

  0.1.0.4 

[ DANTE VERSION ]

 

  DISCONNECT 

 

       

Содержание DSA-2000Q

Страница 1: ...Operation Manual Professional Power Amplifier DSA 500Q 2000Q...

Страница 2: ...shall remain readily accessible CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that c...

Страница 3: ...nt 2 Important safety Instructions 2 Features 3 Contents and Accessories 3 Front Panel 4 Rear Panel 6 Installation Precautions 10 OLED Operating Instructions 11 Applications 23 Block Diagram 27 Specif...

Страница 4: ...s stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the ot...

Страница 5: ...to remote control the device from a PC program OLED SCREEN AT THE FRONT The device features an oleD panel at the front which allows you to configure all settings without connecting to a PC SIMPLE CLEA...

Страница 6: ...be careful not to block the front back of the vents 5 PRT PROTECT MUTE INDICATOR AND LEVEL INDICATOR CH1 CH2 CH3 CH4 1 The PrT MUTe indicator indicates that the device is currently not producing sound...

Страница 7: ...elease the MUTe function 2 Indicator that shows the output level of this device 30 Green 10 Green PrT red 6 CH SELECT MUTE BUTTON CH1 CH2 CH3 CH4 Button that enables you to select the corresponding ch...

Страница 8: ...device from overheating Please be careful not to block the front back of the vents 3 DANTE DIGITAL AUDIO PORT A PorT that facilitates the audio transmission through the Dante network made by Audinate...

Страница 9: ...eaker socket UTP 1 8 1 8 1 8 8 TOP VIEW DIRECT CABLE COLOR ORDER CROSS CABLE CROSS ORDER FRONT VIEW 8 Brown 7 W Brown 6 Green 5 W Blue 4 Blue 3 W Green 3 W Green 2 Orange 1 W Orange 3 CH 2 CH 1 CH 2 C...

Страница 10: ...he device can double the input signal through CH1 or CH3 only therefore make sure not to use CH2 or CH4 2 When you connect the speaker in BrIDGeD mode use PIn 1 and PIn 2 from the 4 Pole speaker Conne...

Страница 11: ...ing the Xlr link Terminal please use a balanced jack If you use an unbalanced jack it may have a significant impact on cable noise Therefore use unbalanced jacks only when devices are grouped closely...

Страница 12: ...cooling therefore when installing in portable rack leave the rear opening clear of obstructions 2 When using power amplifier please install the unit where there is no airflow block to the heat sink F...

Страница 13: ...proximately 10 seconds 2 Switch OFF screen once booting is complete This screen indicates that the power cable has been connected and the power switch remains off but the device has completed its boot...

Страница 14: ...eck the TeMP lIMIT status from the oleD panel at the front or the PC program once the device goes into TeMP lIMIT mode reduce the input level check whether the fAn inside the device is operational and...

Страница 15: ...the CH MUTe button again after selecting a channel you can use the MUTe function for the corresponding channel If you press the button again in MUTe you can return the system to its original sound lev...

Страница 16: ...y Also the integer and decimal points that can be adjusted will be highlighted with a white background as shown in the above image In MenU The In MenU features multiple items including In MoDe In soUr...

Страница 17: ...e MoDe the BrG leD at the front comes on orange 4 2 SOURCE SETTING In soUrCe settings you can distribute the audio signal received through the Xlr InPUT lInK terminal at the back of the device or thro...

Страница 18: ...ot use the BAnK value that has been set If BYPAss is set to off the device uses the BAnK value that has been set for TYPe you can select between PeQ Hsf and lsf GAIn can be set between 15dB and 15dB i...

Страница 19: ...the next letter You can type up to 16 characters In View preset you can check the items you have saved using save preset You can also change the name of the present in View preset by turning the sele...

Страница 20: ...he lIMITer you can select between on and off If the lIMITer is set to on the system will display a sub menu where you can configure releAse ATTACK and THresHolD releAse can be set between 20msec and 4...

Страница 21: ...ond decimal point The initial value is set to 0 00msc If you set the DelAY value the approximate value of the corresponding distance is displayed at the bottom in MeTer units The DelAY range you can s...

Страница 22: ...MAsK address of the current device Initially the device is set to255 255 255 0 GATe displays the GATe WAY address of the current device Initially the device is set to 192 168 1 1 MAC displays the uni...

Страница 23: ...program Please refer to the PC program manual for detailed instructions You can download the PC program manual from our company s official website www inter m net 6 4 FACTORY RESET In fACTorY reseT y...

Страница 24: ...er enCoDer dial at the front of the device left right to select the number you want once you have changed the password press down the seleCT enTer enCoDer dial at the front to save your new password I...

Страница 25: ...e and the eTHerneT PorT on your PC How to connect your PC with 2 or more devices Connect the eTHerneT PorT on the back of the device and the eTHerneT PorT on your PC using a HUB CH CH CH CH 8 300 4 50...

Страница 26: ...r analog How to connect a Pe15 with BrIDGeD MoDe DsA 500Q How to connect an He10 and He15 with BrIDGeD MoDe DsA 500Q BRIDGE MODE DSA 500Q MIXER WR S92L WB S91L WH S91L MIC CDR 01 PE15 BRIDGE MODE PE15...

Страница 27: ...A 5 15s with BrIDGeD MoDe DsA 2000Q How to connect a Pe12 and nlA 5 15s with BrIDGeD MoDe DSA 2000Q MIXER WR S92L WB S91L WH S91L MIC CDR 01 BRIDGE MODE BRIDGE MODE NLA 5 15S NLA 5 15S DSA 2000Q MIXER...

Страница 28: ...o connect a Pe15 with BrIDGeD MoDe How to connect an He10 and He15 with BrIDGeD MoDe DSA 500Q MIXER DASR 288 DANTE AUDIO CONTROLLER WR S92L WB S91L WH S91L MIC CDR 01 PE15 BRIDGE MODE PE15 PE15 DSA 50...

Страница 29: ...LPF 20kHz SIG GRN 10dB GRN LIMITER LPF 20kHz SIG GRN 10dB GRN LIMITER PWM PROTECTION OCP OTP PWM PROTECTION OCP OTP 2nd ORDER LPF HV HV HV HV 2nd ORDER LPF 4dBu 4dBu FAN TEMPERATURE DETECTION SMPS REC...

Страница 30: ...IDGeD Mono MoDe 1600W 800W 4000W 900W Input sensitivity 4dBu 10dBu GAIn sTereo Mono 32dB GAIn BrIDGe 38dB s n Better than 92dB THD 1 3W rated power less than 0 5 less than 0 7 frequency response 1W 0...

Страница 31: ...ProfessIonAl PoWer AMPlIfIer 29 DsA 500Q 2000Q DIMENSIONS 25 420 38 482 88 440...

Страница 32: ...available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Op...

Страница 33: ...noTe...

Страница 34: ...noTe...

Страница 35: ......

Страница 36: ...company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan europe and the U s A With mo...

Отзывы: