4
DOPPIO
DIM
1
DIM
2
N
L
2 3
1
4
Externe
Zuleitung
External
Power
supply
Baldachin
/ Canopy
Stahlseile
Steel cables
SATTLER GmbH Anschlussschema / wiring diagram 20 22.06.2015
G B
R
+
Dim 1
Dim 2
DALI
DA
Dim 1
Dim 2
DMX
–
+
DA
Dimmung /
dimmer
DIM
1
DIM
2
N
L
2 3
1
4
Externe
Zuleitung
External
Power
supply
Baldachin
/ Canopy
Stahlseile
Steel cables
SATTLER GmbH Anschlussschema / wiring diagram 22 22.06.2015
G B
R
+
Dim 1
Dim 2
DALI
DA
Dim 1
Dim 2
DMX
–
+
DA
Dimmung /
dimmer
der Patentert
Dieser Plan is
Inhalts sind n
DIM
1
DIM
2
N
L
Dim 1
Dim 2
0 - 10 V
–
+
Dim 1
Dim 2
1 - 10 V
–
Dim 1
Dim 2
DALI
DA
Dim 1
Dim 2
DMX
–
+
DA
Externe
Zuleitung
External
Power
supply
Baldachin
/ Canopy
Stahlseile
Steel cables
SATTLER GmbH Anschlussschema / wiring diagram 27 22.06.2015
Optional mit Dimmung /
optional with dimmer
+
2
3
+
1
–
4 5
6
+
–
E
1
E
DOPPIO
Assembly instruction
Canopy Ø 350 mm / 13,7“ with 6 steel cables
Canopy Ø 290 mm / 11,4“ with 4 steel cables
Canopy Ø 230 mm / 9,5“ with 4 steel cables
Light fixture with canopy –
Connection of the light fixture
with separate power supply cable
Mounting of the canopy
Make sure the ceiling has sufficient load-carrying
capacity!
1. Fit the base of the canopy to the ceiling with the 4 mounting
points. Ø Drill 6mm / 1/4“ holes and anchor to fasten canopy
to ceiling (see scale sketch on the left).
2. Connect the power supply and the control signal to the terminal
block of the canopy (see wiring diagram E from page 16).
Connection of the light fixture
3. Fix light fixtures with 4 or 6 cables to the canopy at the provided
cable grippers
1
.
4. Lift the light fixture in its desired position and adjust by applying
light pressure on the steel cable grippers. Observe minimum /
maximum suspension height on page 5.
Never adjust the suspension under pressure. The steel
cables might get damaged.
5. When the final position of the light fixture is determined, fix the
lock nut and shorten excessive steel cables in the canopy.
If you want to change the height of the luminaire later, it is also
possible to insulate the steel cables inside the canopy.
Shortened suspension cables can only be replaced at the
factory.
6a. Insert the power supply line through the side of the ceiling plate
and connect it to the terminal block in accordance with the wiring
diagram (p.16-23)
6b (optional) Canopy including light spot: connect pre-assembled
connector to canopy.
7. Mount the canopy cover and fasten it with screws from the side.
8. Check whether the light fixture is functioning.
Canopy with
mounted cover
Canopy
with spot
1
1
/
08
/2018
INTER-LUX
Phone: (410)381-1497
Web: www.inter-lux.com