Fig. 23

Example of Slide Foot on Concrete Pad 

(Side View)

CONCRETE

24” min.

Layer of setting 
material to
secure pavers 
to concrete.

PAVERS

3” 
max.

Drawing Is
NOT To Scale

HEIGHT OF WEDGE
ANCHOR ABOVE
FINAL DECK 
SURFACE 

When installing an Inter-Fab X-Stream™ slide using a paver kit, you must ensure that all
standard installation requirements are met.  The slide must be compatible with the type of
pool on the intended installation and all ANSI/NSPI-2003 requirements must be met.
Refer to installation manual.

Figure 24 illustrates an example of the minimum concrete pads recommended for the 
X-Stream™ slide.  Specific slide positions and concrete pad orientations may vary.  Make
sure to allow for water stub up location near the ladder foot on the X-Stream™ slide when
pouring the concrete pad for the ladder foot.  

In order to ensure proper placement, you

will need to set the slide up first to determine where the concrete pillars will be located.

Figure 23 shows an example side view of a slide foot and an wedge anchor used in a paver
installation.  Pavers can be a maximum of 3” thick.  Pavers must be mechanically attached
to the concrete pad using a setting material (such as mortar or thinset for example) that
is no thicker than 3/8”.  

1” of each 3/8” wedge anchor needs to be exposed above the final deck surface.  You will
need to factor in the thickness of your paver (3” MAX.) and the thickness of your setting
material (3/8” MAX.) for your individual installation.  For the 1/2” wedge anchors, you will
leave 1-1/4” exposed above final deck surface.

You will need a 3/8” masonry bit for the X-Stream™ slide.

Inter-Fab Inc. will not be responsible for damage to pavers caused by drilling or
mechanically attaching to concrete pad.  Refer to paver manufacturer’s specific
installation instructions before beginning.

WEDGE 
ANCHORS

Fig. 24

Minimum Concrete Pads – X-Stream™ Slide 

(Plan View – NOT to Scale)

Pool Edge

3 concrete pads are needed:
24” wide x 24” long x 24” deep
Center each foot on one pad.

You may
rotate the
square pads
as needed.

X-STREAM™ NOTES:

• All X-Stream™ wedge anchors (12 ea.)  are

3/8” x 7”.

• All wedge anchors must be drilled to a depth

of 6” with 1” of the bolt above the final deck
surface.

24” min.

5” min.

from edge

PAVER KIT INFO – X-STREAM

Содержание X-STREAM SLIDE

Страница 1: ...R N O N W A Y T U C S O N A Z 8 5 7 1 3 5 2 0 7 9 0 7 0 4 0 8 0 0 7 3 7 5 3 8 6 F A X 5 2 0 7 9 0 7 1 2 7 i n t e r f a b c o m X S T R E A M S L I D E Assembly Installation Instructions IMPORTANT THE...

Страница 2: ...Entry Section 9 Step 3 Attach Handrails to Ladder Entry Section 9 11 Step 4 Attach Feet to Legs 12 Step 5 Assemble the Flume Sections 12 13 Step 6 Alignment of Flume Sections 13 Step 7 Attach Legs to...

Страница 3: ...THE BOLTS AND ALL THREADS OR THE NUTS MAY SEIZE INTER FAB RECOMMENDS THAT A TWO PERSON CREW ASSEMBLE THE X STREAM SLIDE INTER FAB HIGHLY RECOMMENDS THAT YOU FOLLOW THE INSTALLATION SEQUENCE IN THIS MA...

Страница 4: ...ivery system is on and lubricating the slide prior to use 15 Collision with another swimmer or a diver can result in serious injury or death for one or both persons Before sliding always make sure tha...

Страница 5: ...s 4 6 from the back wall of the pool A minimum depth of four feet 4 must be maintained at a distance of nine feet 9 along the centerline of the slide from point A The above described water depth profi...

Страница 6: ...N U A L X S T R E A M S L I D E 5 XS IM Rev 7 08 SBK XS INSTALL SLIDE PLACEMENT DIAGRAM FOOTPRINT DIAGRAM X Stream Slide Left Turn DIAGRAM D NOT TO SCALE DIAGRAM E NOT TO SCALE RECOMMENDED MIN DECK AR...

Страница 7: ...U A L X S T R E A M S L I D E 6 XS IM Rev 7 08 SBK XS INSTALL SLIDE PLACEMENT DIAGRAM FOOTPRINT DIAGRAM X Stream Slide Right Turn DIAGRAM F NOT TO SCALE DIAGRAM G NOT TO SCALE RECOMMENDED MIN DECK AR...

Страница 8: ...in that order For a Right Hand Slide C D is the upper flume and A B is the lower flume Flumes are labeled A B or C D in small letters centered on flanges A B Flume C D Flume Hardware Kits 5 Bottom Se...

Страница 9: ...ides flume C D is the upper flume and A B is the lower STEP ONE Attach Ladder Foot to Ladder TIP The leg foot elephant foot for the ladder has a slant inside the other 2 feet do not slant The ladder f...

Страница 10: ...lock washer over a 3 8 bolt then flat washer then push bolt through the pre drilled holes in the PVC ladder into the nuts embedded in the entry section leg receiver and tighten Fig 2 Ladder Step Suppo...

Страница 11: ...thread 2 2 x5 16 all thread 3 2 1 2 x5 16 all thread Make sure to use provided anti seize on the all thread before inserting into the embedded nuts Insert handrail into the top section first as illus...

Страница 12: ...fore attaching the flange nuts These two locations require a flat washer flange nut and rubber cap Hand tighten Make sure to use the provided lubricant on the all threads before attaching the flange n...

Страница 13: ...lide use the cardboard box for protection Hand tighten the flume bolts for now they will be fully tightened once the flume is correctly aligned Right Turn or Left Turn Assembly The flumes are labeled...

Страница 14: ...ns and the exit section are bolted together hand tight then gently push or pull on the flume sections to ensure a smooth even alignment of the sliding surface Next starting with the exit section tight...

Страница 15: ...the entry section with the 4 holes in the Upper Flume Section and gently push them through Place a 3 8 flat washer then lock washer and then a 3 8 nut on each all thread Ensure a smooth even alignmen...

Страница 16: ...it is not possible to drill the anchor bolt holes with the slide in place gently move the slide to one side allowing sufficient room to drill the anchor bolt holes Anchor bolts are in Hardware Kit XS...

Страница 17: ...4 Inspect the runway for visible cracks or tears 5 Inspect the runway and ensure a smooth even sliding surface Ensure the gaskets between the flanges are compressed uniformly 6 Inspect the runway for...

Страница 18: ...g material from entering the pool Wash with a mild soap such as hand dishwashing soap avoid using strong cleaners or abrasives Avoid strong alkaline such as tri sodium phosphate or highly acidic clean...

Страница 19: ...xample side view of a slide foot and an wedge anchor used in a paver installation Pavers can be a maximum of 3 thick Pavers must be mechanically attached to the concrete pad using a setting material s...

Страница 20: ...asher s s 8 H SS 3 8 X 3 TAP 3 8 x 3 hex head tap bolt s s 20 H 562 X 390 CAP gray protective cap XS 103 SS PVC LEG TO FLUME QTY PART NUMBER COMPONENT DESCRIPTION 12 H SS 3 8 16X2 3 8 x 2 hex head bol...

Страница 21: ...I N S T A L L A T I O N M A N U A L X S T R E A M S L I D E 20 XS IM Rev 7 08 SBK XS INSTALL X STREAM SLIDE XS GR SS...

Страница 22: ...X 310 CAP GRAY PROTECTIVE CAP 10 14 H 562 X 390 CAP GRAY PROTECTIVE CAP 11 20 12 12 15 H SS 3 8 F NUT 3 8 FINISH NUT S S 12 16 H SS 3 8 FLT WASHER 3 8 X 1 FLAT WASHER S S 22 20 12 17 H SS 3 8 LOC WASH...

Страница 23: ...1 year from the date of retail purchase Unless expressly stated otherwise all products manufactured by Inter Fab are for residential installation and use only Inter Fab Inc expressly disclaims any and...

Отзывы: