Page 51
Intepro Systems
www.inteproate.com
PS 9000 3U Series
Submenu “
IP Settings 1
”
Element
Description
Get IP address
Manual
(default): uses the default (after delivery or reset) or the last set network parameters.
Those parameters are not overwritten by selection “
DHCP
” and remain when switching back
from “
DHCP
” to “
Manual
”
DHCP
: after switching to DHCP and submitting the change with button
, the device will
instantly try to get network parameters (IP, subnet mask, gateway, DNS) assigned from a
DHCP server. If the attempt fails, the device will use the settings from “
Manual
” again.
IP address
Only available with setting “
Get IP address = Manual
”. Default value: 192.168.0.2
Permanent manual setting of the device’s IP address in standard IP format
Subnet mask
Only available with setting “
Get IP address = Manual
”. Default value: 255.255.255.0
Permanent manual setting of the subnet mask in standard IP format
Gateway
Only available with setting “
Get IP address = Manual
”. Default value: 192.168.0.1
Permanent manual setting of the gateway address in standard IP format
Submenu “
IP Settings 2
”
Element
Description
Port
Default value: 5025
Adjust the socket port here, which belongs to the IP adress and serves for TCP/P access
when controlling the device remotely via Ethernet
DNS address
Default value: 0.0.0.0
Permanent manual setting of the network address of a domain name server (short: DNS)
which has to be present in order to translate the host name to the device’s IP, so the device
could alternatively access by the host name
Enable TCP keep-
alive
Default setting: No
Activates/deactivates the so-called “keep-alive” functionality of Ethernet connections
Submenu “
Communication Protocols
”
Element
Description
Enabled
Enables or disables SCPI or ModBus communication protocols for the device. The change is
immediately effective after submitting it with ENTER button. Only one of both can be disabled.
Submenu “
Communication Timeout
”
Element
Description
Timeout USB (ms)
Default value: 5, Range: 5...65535
USB/RS232 communication timeout in milliseconds. Defines the max. time between two
subsequent bytes or blocks of a transferred message. For more information about the
timeout refer to the external programming documentation “Programming ModBus & SCPI”.
Timeout ETH (s)
Default value: 5, Range: 5...65535
Defines a timeout after which the device would close the socket connection if there was no
communication between the controlling unit (PC, PLC etc.) and the device for the adjusted
time. The timeout is ineffective as long as option “TCP Keep-alive” (see above) is enabled
and the keep-alive functionality of the network is active.
Submenu “
Node address
” (only displayed for devices with GPIB interface)
Element
Description
Node address
Default value: 1
Adjusts the primary GPIB address for the GPIB port which is available with installed option
3W. Address range: 1...30. Secondary address isn’t used.