Page 48
Intepro Systems
www.inteproate.com
PS 9000 3U Series
3.4
Manual operation
3.4.1 Switching the device on
The device should, as far as possible, always be switched on using the rotary switch on the front of the device.
Alternatively this can take place using an external cutout (contactor, circuit breaker) of suitable current capacity.
After switching on, the display will show the manufacturers logo for a few seconds, plus some information like
device model, firmware version(s), serial number and item number and will then be ready for use. In setup (see
section
„3.4.3. Configuration in the setup menu“)
in the second level menu “
General settings
” is an option “
Output
after power ON
” in which the user can determine the condition of the DC output after power-up. Factory setting
here is “
OFF
”, meaning that the DC output on power-up is always switched off. Selection “
Restore
” means that
the last condition of the DC output will be restored, either on or off. All set values are always saved and restored.
For the time of the start phase the analog interface can signal undefined statuses on the output
pins such as OT or OVP. Those signals must be ignored until the device has finished booting
and is ready to work.
3.4.2
Switching the device off
On switch-off the last output condition and the most recent set values are saved. Furthermore, a PF alarm (power
failure) will be reported, but can be ignored.
The DC output is immediately switched off and after a short while fans will shut down and after another few seconds
the device will be completely powered off.
3.4.3
Configuration in the setup menu
The setup menu serves to configure all operating parameters which are not constantly required. It can be entered
by pushing
, but only while the DC output is switched off. See figures below.
If the DC output is switched on the settings menu will not be shown, but the quick menu and some status information.
Menu navigation is done with the pushbuttons
,
and
. Parameters (values, settings) are set using
the rotary knobs.
The assignments of the rotary knobs, if multiple values can be set in a particular menu, is always the same: pa
-
rameters on the left-hand side -> left-hand knob, parameters on the right-hand side -> right-hand knob
Some setting parameters are self-explan
-
atory, others are not. The latter will be
explained on the pages following.