2

2.    ATTACHED FITTINGS 

Please check whether the following fittings are of full scope. If there 

are some spare fittings , please restore them carefully. 

QUANTITY

INSTALLATION 

FITTINGS

SHAPE

NAME

1. Outdoor unit 

installation manual

2. Outdoor unit 

owner’s manual

1

1

1

1

2

2

1

1

Be sure to provide grounding.

Do not connect ground wires to gas pipes, water pipes, lightning rods 

or ground wires for telephone cables.

Conform to the regulations of the local electric company when 

wiring the power supply.

Inappropriate grounding may cause electric shock.

Do not install the air conditioner in a location subject to a risk 

of exposure to a combustible gas.

If a combustible gas leaks, and stays around the unit, a fire may occur.

6)  Reamer

7)  Gas leak detector

8)  Tape measure

9)  Thermometer

10) Mega-tester

11) Electro circuit tester

12) Hexagonal wrench

13) Flare tool

14) Pipe bender

15) Level vial

16) Metal saw

17) Gauge manifold (Charge hose:R410A special requirement)

18) Vacuum pump (Charge hose:R410A special requirement)

19) Torque wrench 

                  1/4(17mm)16N•m (1.6kgf•m)

                  3/8(22mm)42N•m (4.2kgf•m)

                  1/2(26mm)55N•m (5.5kgf•m)

                  5/8(15.9mm)120N•m (12.0kgf•m)

20) Copper pipe gauge adjusting projection margin

21) Vacuum pump adapter

Required tools for installation work

1)  Philips screw driver                    

2)  Hole core drill(65mm)

3)  Spanner

4)  Pipe cutter

5)  Knife 

Refrigerant Piping 

Piping kit used for the conventional refrigerant cannot be used.

Use copper pipe with 0.8 mm or more thickness for φ9.5.

Use copper pipe with 1.0 mm or more thickness for φ15.9.

Use copper pipe with 1.0 mm or more thickness for φ19.0.

Flare nut and flare works are also different from those of the 

conventional refrigerant. Take out the flare nut attached to the main

unit of the air conditioner, and use it.

Before installation

Be careful to the following items before installation.

Air purge

For air purge, use a vacuum pump.

Do not use refrigerant charged in the outdoor unit for air  purge. 

(The refrigerant for air purge is not contained in the outdoor unit.)

Electrical cabling

Be sure to fix the power cables and indoor/outdoor  connecting 

cables with clamps so that they do not contact with the cabinet, etc.

Installation Place 

A place which provides a specified space around the outdoor unit.

A place were the operation noise and discharged air are not given

to your neighbors. 

A place that is not exposed to a strong wind.

A place that does not block a passage.

When the outdoor unit is installed in an elevated position, make

sure it's four feet securely installed.

There must be sufficient space for carrying in the unit.

A place where the drain water does not make any problem.

3. Water outlet 

pipe connector

6.Network matching 

wires

5.Rubber wire ring

(36/42kBtu/h)

4.Seal ring(28kBtu/h)

8.Connecting pipe

(48kBtu/h)

7.Connecting pipe

(56kBtu/h)

NOTE

Check if any accessory in the above figure is missing. All the 

accessories must be kept properly.

All the fittings should be Intensity fittings.

Wired/Remote controller — purchase separately 

Outlet sealant — purchase separately.

All the figures in the manual explain only the general appearance 

and dimensions of the unit. The air conditioner you purchased 

may not be completely consistent with the appearance and 

functions listed in the figures. Please refer to the actual product.

2000

Fig.2-1

When installing the outdoor unit in a place that is constantly 

exposed to a strong wind such as the upper stairs or rooftop of a 

building, apply the windproof measures referring to the following 

examples.

Install the unit so that its discharge port faces to the wall of the 

building. Keep a distance of 2000mm or more between the unit 

and the wall surface.

CAUTION

   Install the outdoor unit at a place where discharge air is not blocked.

   When an outdoor unit is installed in a place that is always exposed 

   to a strong wind like a coast or on a high storey of a building, secure 

   a normal fan operation by using a duct or a wind shield.

Содержание BlackSeries DIVERSE MDV-V28W/DHN1(At)

Страница 1: ...DHN1 At MDVC V42W DHN1 At MDVC V48W DHN1 At MDVC V56W DHN1 At MDV V28W DHN1 At MDV V36W DHN1 At MDV V42W DHN1 At MDV V48W DHN1 At MDV V56W DHN1 At DIVERSE Thank you very much for purchasing our air c...

Страница 2: ...ce RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule The power cord type designation is H05RN R H07RN F or above Ask an authorized dealer or qu...

Страница 3: ...mp Do not use refrigerant charged in the outdoor unit for air purge The refrigerant for air purge is not contained in the outdoor unit Electrical cabling Be sure to fix the power cables and indoor out...

Страница 4: ...ficient ventilation place Near a private power station or high Frequency equipment The insulation of the metal parts of the building and the air conditioner should comply with the regulation of Nation...

Страница 5: ...units refer to Fig 3 7 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind refer to Fig 3 7 Since the gravity center of the unit is not a...

Страница 6: ...hile connect to the connecting pipes outside and then piping and wiring through this Pay attention to the piping the fat connecting pipe should out from the largest hole otherwise the pipes will be ru...

Страница 7: ...able 4 4 the air liquid side of L2 is 15 9 9 5 N1 28 N3 28 N5 28 N6 22 N2 28 N4 28 A B D E C a b c e f d L1 L2 L5 L3 L4 The straight distance between copper pipe turning and the contiguous branch pipe...

Страница 8: ...should not longer than 15m Indoor unit branch pipe The main pipes of indoor unit and the indoor unit branch pipe components The downstream inner units of the main pipe L2 are N1 N2 and its total capa...

Страница 9: ...h 20m 36 42kBtu h 20m 48 56kBtu h Drop HEIGHT between indoor unit and outdoor unit The first connect method Indoor Unit The First Line Branch Pipe Outdoor unit a A L2 L1 B C D E L3 L4 L5 b c d e f Fig...

Страница 10: ...er enters the pipes After the above vacuum drying of two hours use nitrogen to increase the pressure to 0 05 MPa vacuum breaking and use a vacuum pump to decrease the pressure to lower than 100 7kPa o...

Страница 11: ...u h Hz Voltage Min V Max V MCA TOCA MFA MSC RLA kW FLA 220 240V 1Ph 50 60Hz Power Supply Compressor OFM Power Source PQE PQE PQE L N P Q E X Y E Outdoor power supply Indoors Power supply ODU IDU IDU I...

Страница 12: ...ntroller Wired controller P Q E P Q E X Y E Please use the shielded wire and the shield layer must be grounded Note The wired controller and centralized controller in the dashed box are optional acces...

Страница 13: ...Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary In broken line table users can purchase the wire controller...

Страница 14: ...ustomers in details Please press constraint cool button to carry out refrigerant recycling process Keep the low pressure above 0 2MPa other wise compressor may be burnt out Fig 7 1 NOTE 7 1 Important...

Отзывы: