1.    PRECAUTIONS 

CAUTION

CONTENTS

PAGE

PRECAUTIONS........................................................................................1

ATTACHED FITTINGS..............................................................................2

OUTDOOR UNIT INSTALLATION..............................................................3

INSTALL THE CONNECTING PIPE............................................................5

ELECTRICAL WIRING..............................................................................9

TEST RUNNING.....................................................................................11

PRECAUTIONS ON REFRIGERANT LEAKAGE.........................................12

TURN OVER TO CUSTOMER..................................................................12

Ensure that all Local, National and International regulations 

are satisfied.

Read this ”PRECAUTIONS ” carefully before Installation. 

The precautions described below include the important 

items regarding safety. Observe them without fail.

After the installation work, perform a trial operation to check

for any problem.

Follow the Owner’s Manual to explain how to use and 

maintain the unit to the customer.

Turn off the main power supply switch (or breaker) before 

maintenance the unit .

Ask the customer that the Installation Manual and the Owner’s

Manual should be kept together .

New Refrigerant Air Conditioner Installation

WARNING

THIS AIR CONDITIONER ADOPTS THE NEW HFC 

REFRIGERANT(R410A)WHICH DOES NOT DESTROY OZONE

LAYER.

The characteristics of  R410A refrigerant are; Hydrophilic, oxid-

izing membrane or oil, and its pressure is approx.1.6 times high-

er than that of refrigerant R22. Accompanied with the new refrig-

erant, refrigerating oil has also been changed ,Therefore, during

 installation work, be sure that water, dust, former refrigerant, or

 refrigerating oil does not enter the refrigerating cycle.

To prevent charging an incorrect refrigerant and refrigerating oil, 

the sizes of connecting sections of charging port of the main 

unit and installation tools are charged from those for the 

conventional refrigerant.

Accordingly the exclusive tools are required for the new 

refrigerant (R410A):

For connecting pipes, use new and clean piping designed for 

R410A,and please care so that water or dust does not enter. 

Moreover, do not use the existing piping because there are 

problems with pressure-resistance force and impurity in it.

CAUTION

Do not connect the Appliance from Main Power Supply.

This unit  must be connected to the main power supply by 

means of a switch with a contact separation of at least 3 mm.

The installation fuse must be used for the power supply line of 

 this conditioner.

If the supply cord is damaged, it must be replaced by the 

manufacturer or its service agent or a similarly qualified person 

in order to avoid a hazard.

An all-pole disconnection switch having a contact separation of 

at least 3mm in all poles should be connected in fixed wiring.

The appliance shall be installed in accordance with national 

wiring regulations.

The temperature of refrigerant circuit will be high, please keep 

the interconnection cable away from the copper tube.

An all-pole disconnection device which has at least 3mm 

separation distance in all pole and a residual current 

device(RCD)with the rating of above 10mA shall be incorporated 

in the fixed wiring according to the national rule.

The power cord type designation is H05RN-R/H07RN-F or above.

Ask an authorized dealer or qualified installation professional to

install/maintain the air conditioner.

Inappropriate installation may result in water leakage,electric shock

or fire.

Turn off the main power supply switch or breaker before 

attempting any electrical work.

Make sure all power switches are off. Failure to do so may cause 

electric shock.

Connect the connecting cable correctly.

If the connecting cable is connected in a wrong way, electric parts 

may be damaged.

When moving the air conditioner for the installation into another

 place, be very careful not to enter any gaseous matter other

 than the specified refrigerant into the refrigeration cycle.

If air or any other has is mixed in refrigerant, the gas pressure in the 

refrigeration cycle becomes abnormally high and it may resulting

causes pipe burst and injuries on persons.

Do not modify this unit by removing any of the safety guards or

by by-passing any of the safety interlock switches.

Exposure of unit to water or other moisture before installation 

may cause a short-circuit of electrical parts.

Do not store it in a wet basement or expose to rain or water.

After unpacking the unit, examine it carefully if there are 

possible damage.

Do not install in a place that might increase the vibration of the 

unit.

To avoid personal injury (with sharp edges), be careful when 

handling parts.

Perform installation work properly according to the Installation 

Manual.

Inappropriate installation may result in water leakage, electric shock 

or fire.

When the air conditioner is installed in a small room, provide 

appropriate measures to ensure that the concentration of 

refrigerant leakage occur in the room does not exceed the 

critical level.

Install the air conditioner securely in a location where the base 

can sustain the weight adequately.

Perform the specified installation work to guard against an 

earthquake.

If the air conditioner is not installed appropriately, accidents may 

occur due to the falling unit.

If refrigerant gas has leaked during the installation work, 

ventilate the room immediately.

If the leaked refrigerant gas comes in contact with fire, noxious gas 

may generate.

After the installation work, confirm that refrigerant gas does not 

leak.

If  refrigerant gas leaks into the room and flows near a fire source, 

such as a cooking range, noxious gas might generate.

Electrical work must be performed by a qualified electrician in 

accordance with the Installation Manual. Make sure the air 

conditioner uses an exclusive power supply. 

An insufficient power supply capacity or inappropriate installation 

may cause fire.

Use the specified cables for wiring connect the terminals 

securely fix. To prevent external forces applied to the terminals

from affecting the terminals.

Содержание BlackSeries DIVERSE MDV-V28W/DHN1(At)

Страница 1: ...DHN1 At MDVC V42W DHN1 At MDVC V48W DHN1 At MDVC V56W DHN1 At MDV V28W DHN1 At MDV V36W DHN1 At MDV V42W DHN1 At MDV V48W DHN1 At MDV V56W DHN1 At DIVERSE Thank you very much for purchasing our air c...

Страница 2: ...ce RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule The power cord type designation is H05RN R H07RN F or above Ask an authorized dealer or qu...

Страница 3: ...mp Do not use refrigerant charged in the outdoor unit for air purge The refrigerant for air purge is not contained in the outdoor unit Electrical cabling Be sure to fix the power cables and indoor out...

Страница 4: ...ficient ventilation place Near a private power station or high Frequency equipment The insulation of the metal parts of the building and the air conditioner should comply with the regulation of Nation...

Страница 5: ...units refer to Fig 3 7 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind refer to Fig 3 7 Since the gravity center of the unit is not a...

Страница 6: ...hile connect to the connecting pipes outside and then piping and wiring through this Pay attention to the piping the fat connecting pipe should out from the largest hole otherwise the pipes will be ru...

Страница 7: ...able 4 4 the air liquid side of L2 is 15 9 9 5 N1 28 N3 28 N5 28 N6 22 N2 28 N4 28 A B D E C a b c e f d L1 L2 L5 L3 L4 The straight distance between copper pipe turning and the contiguous branch pipe...

Страница 8: ...should not longer than 15m Indoor unit branch pipe The main pipes of indoor unit and the indoor unit branch pipe components The downstream inner units of the main pipe L2 are N1 N2 and its total capa...

Страница 9: ...h 20m 36 42kBtu h 20m 48 56kBtu h Drop HEIGHT between indoor unit and outdoor unit The first connect method Indoor Unit The First Line Branch Pipe Outdoor unit a A L2 L1 B C D E L3 L4 L5 b c d e f Fig...

Страница 10: ...er enters the pipes After the above vacuum drying of two hours use nitrogen to increase the pressure to 0 05 MPa vacuum breaking and use a vacuum pump to decrease the pressure to lower than 100 7kPa o...

Страница 11: ...u h Hz Voltage Min V Max V MCA TOCA MFA MSC RLA kW FLA 220 240V 1Ph 50 60Hz Power Supply Compressor OFM Power Source PQE PQE PQE L N P Q E X Y E Outdoor power supply Indoors Power supply ODU IDU IDU I...

Страница 12: ...ntroller Wired controller P Q E P Q E X Y E Please use the shielded wire and the shield layer must be grounded Note The wired controller and centralized controller in the dashed box are optional acces...

Страница 13: ...Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary In broken line table users can purchase the wire controller...

Страница 14: ...ustomers in details Please press constraint cool button to carry out refrigerant recycling process Keep the low pressure above 0 2MPa other wise compressor may be burnt out Fig 7 1 NOTE 7 1 Important...

Отзывы: