Intelligent Intell-Lab PH Series Скачать руководство пользователя страница 39

39

20 Maximum load determination function

*The balance must be equipped with the specific optional software (not available for all models)*

The function

M LOAD

allows to measure the maximum load for a solid.

1. To activate the function M LOAD from zero display condition, press repeatedly the

MENU

button until the message

“M Load”

is displayed, then press the

PRINT

button

to confirm. When this function is activated, a tare is automatically performed.

2. Activation of this function is indicated by the visualization of the letter

M

on the last

digit on the display.

3. It is now possible to determine the weight of the maximum load.

4. Then

press

the

TARE

button to

effect

another

measurement.

5. When the function

M LOAD

is active, the calibration is disabled.

6. Press the button

ON/OFF

to escape from

M LOAD

function.

Содержание Intell-Lab PH Series

Страница 1: ...June 2009 Intell Lab Precision Toploading Balances PH Series User Operation Manual A Higher Level of Precision A Higher Level of Performance...

Страница 2: ...tare function Not available for V range models 15 7 1 2 Optional alphanumeric external keyboard code T201 16 8 WEIGHT UNITS 18 9 PC COMMUNICATION SETTING 20 10 PRINTER SERIAL COMMUNICATION SELECTION...

Страница 3: ...ION HI LO GO 42 22 1 BOTH THRESHOLDS SET 43 22 2 LOWER THRESHOLD SET ONLY 43 22 3 HIGHER THRESHOLD SET ONLY 43 23 RS232 INTERFACE FEATURES 44 24 CONNECTORS POSITIONS REAR 49 25 WORKING WITH THE BATTER...

Страница 4: ...vibrations Do not use the balance in explosion risk environment The humidity rate of the balance environment must be between 45 and 75 Place the weighing pan and the support pan on the balance see pag...

Страница 5: ...parts used must be original Therefore it is necessary to apply to the reseller who sold the equipment 2 Storage Storage temperature 5 C 40 C Storage humidity 45 75 Keep package in the case the balance...

Страница 6: ...isplay Standby OFF or power on ON TARE or zero button O PC Selection CONFIRM or SEND data to printer Stability indicator Zero indicator Percentage weighing Piece counting Battery charge indicator Inse...

Страница 7: ...3 7 Balance setup MENU button Balance CALIBRATION button H L DS ct ozt lb GN dwt Kg mg...

Страница 8: ...rt of balance K model 1 Weighing pan 2 CONNECTOR 1 9 pin RS232 Interface Output for PC keyboard or printer 3 levelling feet 4 CONNECTOR 2 power supply connector 5 Level Bubble 0 Closing screws 2 Hook...

Страница 9: ...balance will set itself in stand by mode 5 1 Stand By From STAND BY mode Press ON OFF button to bring balance to work conditions Press again ON OFF button to return to STAND BY condition 5 2 Simple w...

Страница 10: ...CAL button 1 Press CAL button when pan is empty dashes are displayed on the display 2 When calibration weight value starts to flash load the weight on the pan The display will stop flashing indicatin...

Страница 11: ...ight as long as it is a whole number in comparison with the most meaningful digit of calibration weight e g if calibration weight is 200g it will be possible to calibrate the balance with values from...

Страница 12: ...essed the PRINT button until the acoustic alarm is over 3 After selection the balance returns to calibration menu Press and keep pressed MENU button until the acoustic alarm is over then release the b...

Страница 13: ...nal calibration Follow procedures described at paragraph 6 1 1 6 2 5 Technical calibration TEC CAL This function allows storing the value of internal reference mass whenever checking or assistance act...

Страница 14: ...ight balance returns to normal weighing conditions 6 Return to calibration menu as described at paragraph 6 2 and set the desired calibration mode internal automatic or external ATTENTION this procedu...

Страница 15: ...O T button O t string will be displayed 3 After reaching stability the value 0 000 will be displayed If the stability is not reached due to air flows or vibrations or other disturbs the dashes will re...

Страница 16: ...the beep alarm stops and then release the key 2 Will be shown on the display the following string 3 Insert now the desired tare value using the keys CAL and MENU for increase or decrease the value an...

Страница 17: ...tare also by pressing the TARE DELETE button of this keyboard in the same way as previously described It s also possible to manually insert a known tare value by the keypad 1 Press TARE MAN button on...

Страница 18: ...art of alphanumeric keyboard 3 Press INSER to confirm 4 Press ESCAPE button to escape from tare condition To set to zero the value of the manual tare inserted by means of alphanumeric keyboard effect...

Страница 19: ...ressing now the MENU or CAL button it will be possible to scroll forward or backward the weight units menu 3 Press PRINT button to confirm or MENU button to shift to the other weight unit SYMBOL UNIT...

Страница 20: ...the button The balance returns to normal weighing conditions The unit of measure with the star are not available in the balances with the software for paper grammage In these models is possible to se...

Страница 21: ...cont is displayed to choose continuous print or PC CMd to choose print to PC at user command and then press the PRINT button to confirm the choice 6 After having selected the desired transmission mode...

Страница 22: ...splay and confirm pressing PRINT button 2 T o s e l e ct the data print mode press MENU until the message PRINT is displayed 3 Press PRINT to confirm 4 After having selected the data print mode press...

Страница 23: ...smission speed 1200 2400 4800 9600 baud Pressing MENU or CAL buttons it will be possible to scroll forward or backward trough the different transmission speeds and then confirm your choice by pressing...

Страница 24: ...condition on display press and keep pressed the MENU button until the acoustic alarm is over and then release the button The message unitS is displayed then press MENU button until the message AUTO 0...

Страница 25: ...ions thanks to the selection of three filters FILTER 1 Ideal conditions and filling applications FILTER 2 stable conditions FILTER 3 unstable conditions 1 From zero condition on display press and keep...

Страница 26: ...eter or CAL to go to previous one 4 To escape from parameters setup menu press the MENU button until the acoustic alarm is over then release the button 5 The balance will return to standard weighing c...

Страница 27: ...button until the message StAbiL is displayed and then confirm this by pressing the PRINT button 2 Pressing MENU or CAL button it will be possible to scroll forward or backward the different stability...

Страница 28: ...The message unitS is displayed then press MENU button until the message bLt then press the PRINT button to confirm this 2 Pressing MENU or CAL button it will be possible to scroll forward or backward...

Страница 29: ...ver then release the button The message unitS is displayed then press MENU button until the message tiME oFF then confirm by pressing the PRINT button 2 Pressing MENU or CAL button it will be possible...

Страница 30: ...ess PRINT to confirm Load on the pan the number of pieces displayed on the balance display Press again the PRINT button and wait the weight to stabilize If the number of samples is enough for example...

Страница 31: ...t will be possible to go on with count by loading the pieces count on the balance pan 3 To escape from piece counting mode press the ON OFF button and the balance returns to normal weighing conditions...

Страница 32: ...ecreases the value and use the O T button to skip to the others digits For inserting the decimal point keep pressed the CAL button Keeping pressed the O T button is possible to delete the inserted val...

Страница 33: ...e weight is enough then 0 is displayed it is now possible to go on to count loading the pieces on the pan 7 Press MENU button to display the total number of pieces then press again the button to displ...

Страница 34: ...ally performed at the end of which it is possible to operate with the highest resolution range 2 The range change is pointed out by the switch on of a small arrow on the display 3 The range of highest...

Страница 35: ...zero condition on display press the MENU button until the message dEnS is displayed then press the PRINT button to confirm 2 Select the functio n d SoLid throug h the MENU button and then confirm with...

Страница 36: ...essage WEI AIR will be flashing 9 Now it is asked to weigh the solid inside the liquid Effect the tare of the small basket inside liquid immerse the solid and press PRINT During the acquisition of the...

Страница 37: ...e value of the density of the glass float of known volume to use the default value is equal to 3 0000 4 It is possible to set a different value using the CAL e MENU buttons for increase and decrease t...

Страница 38: ...rsed into the liquid Perform a tare if necessary and immerse the glass float into the liquid Press the PRINT button During the acquisition of the value the message WEI LIq will be flashing 10 The resu...

Страница 39: ...til the message M Load is displayed then press the PRINT button to confirm When this function is activated a tare is automatically performed 2 Activation of this function is indicated by the visualiza...

Страница 40: ...m zero condition of the display press the MENU button until will be displayed the Perc message then press the PRINT button to confirm 2 Press the MENU button to select the Perc A function and press PR...

Страница 41: ...rom zero condition of the display press the MENU button until will be displayed the Perc message then press the PRINT button to confirm 2 Press the MENU button to select the Perc A function and press...

Страница 42: ...ualize the weight in gram and vice versa 6 Press the ON OFF button to escape from the percentage weight function 7 It is also possible to set the value if the balance is equipped with the optional alp...

Страница 43: ...the CAL e MENU buttons for increase and decrease the value and using the O T button for skip to the others digits Keeping pressed the O T button is possible to delete the inserted value The inserted v...

Страница 44: ...shold value set will be displayed the symbol L while if the weight is over the higher threshold value set will be displayed the symbol H 22 2 Lower threshold set only Setting only the lower threshold...

Страница 45: ...e selected as described previously pag 19 to 1200 2400 4800 e 9600 baud The character format is of 8 bit preceded by one bit of start and followed by a bit of stop Parity is not considered 2 Selection...

Страница 46: ...5 Transmission format String transmitted is composed by the following 14 characters First character weight sign blank or second ninth character weight or other data tenth twelfth character weight unit...

Страница 47: ...eight of pieces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Weight space Value of weight space g space S Average unit weight of pieces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PMU spaces Va...

Страница 48: ...n is the number 1 fig 1 pag 46 8 Connection of the balance with the serial printer Connect a serial printer to connector 1 to the balance as shown in the following scheme Balance 2 side 4 Connector 1...

Страница 49: ...ic keyboard To connect the optional alphanumeric keyboard it must be used the connector 1 the same used for connection to a PC In this case the connection to PC or to printer must be effected through...

Страница 50: ...Connector 2 Power supply connector Fig 1 Rear of the balance Fig 2 Fig 3 CONNECTOR 1 CONNECTION FOR KEYPAD PC AND PRINTER pin 1 Power 5V for keyboard pin2 Txsignal pin3 Rxsignal pin 4 busy signal pin...

Страница 51: ...necessary to connect the balance to AC power outlet to re charge the battery Failure to do so will damage the battery This is NOT covered by warranty 1 To re charge the battery connect the external po...

Страница 52: ...balance requires to be re calibrated Unload weights if any on the pan and press the CAL button Overange condition Unload the weights loaded on the pan Underange condition Place properly pan and under...

Страница 53: ...PRINT button to confirm the choice To escape from menu press and keep pressed the MENU button until the acoustic alarm is over Units Pc Print Baud rt Auto 0 Filter Stabil Blt Time Off Calib End br 120...

Страница 54: ...and keep pressed the MENU button until the acoustic alarm is over Smlp 10 Smlp 25 Smlp 50 Smpl 100 Manual D solid D liquid L threshold Perc A Perc M Tare dl 1 0000 ds 3 0000 H threshold t 0 Ins weigh...

Страница 55: ...delivery note 2 Warranty covers all parts resulting defective at the origin It does not cover mechanical or electronic parts damaged by wrong installation tampering or incorrect use 3 Warranty does no...

Страница 56: ...measurement industry both in the USA and worldwide With contacts in over 50 countries we provide you with the weighing and measurement equipment you need QUALITY Products solidly built from the ground...

Отзывы: