Installation 

1.

 

Install a wall box.

 

Install a flush mounting wall box as per diagram 1

 

NB. If a wall box is not used the power cable will 
not sit flush with the wall and prevent the unit from 
being firmly installed against the wall. 

 
 
2.

 

Install the mounting panel to the wall 

Install the mounting plate supplied with the hand  
dryer to the wall using appropriate fixings. At least  
6 fixings should be used as indicated.  
Make sure wall is capable of suporting the weight  
of the dryer before installing the installation panel 
 
 

 
 
 

Connecting to Fixed wiring

 

1) Terminate the cable from the hand dryer into the  
flush mounting wall box. 
2) Attach the dryer to the wall using the 3 hooks on  
the mounting panel. 
3) Secure the dryer to the mounting plate with the  
fixing screw in the lower right side (behind the drip  
tray)  

The installation screw will not tighten if the lower  
hook is not completely inserted. Ensure the dryer is  
fixed to the installation panel with the fixing screw  
otherwise the dryer is liable to be damaged when it is  
subjected to knocks etc during use. 
 
 
 

Important 

 
Do not operate the power or heat switches with your hands inside the dryer opening.  
 
If the self check indicator on the display lights or is flashing, turn off the power switch, 
wait 1 minute, and then turn the power switch back on  

 

 

 

Содержание ATC-Premblade15

Страница 1: ...INTELLIGENT FACILITY SOLUTIONS Electric Works 3 Concourse Way Sheffield S1 2BJ United Kingdom Phone UK 44 0 114 354 0047 Phone Eire 353 190 36387 sales ihdryers co uk https www intelligenthanddryers com ...

Страница 2: ...1 Hand Dryer Model ATC Premblade15 Installation User Manual Issue number 1 ...

Страница 3: ...outine Cleaning 7 Troubleshooting Electrical Diagram 8 Part Names and Dimensions 9 Warranty 10 This hand dryer should be installed by a qualified electrician or a trained service technician Read this manual thoroughly before using the hand dryer to ensure safe and correct operation Please keep this manual in a safe place for reference at a later date ...

Страница 4: ...V 95 m s Sensor Adjustable or Fixed Fixed Noise Level dB 1m 70 Filter Replaceable HEPA Approvals RoHS CE CB UL Motor thermal Protection Turns unit off at 95ºC Heater Thermal Protection Turns unit off at 100ºC IP Rating X4 Dimensions WxHxD mm 300 x 700 x 215 Weight 9 5kg Packing List ATC PremBlade15 1 Installation Plate 1 Cleaning Brush 1 5mm Plastic Wall Plug 6 5x 30mm Self tapping screws 6 User M...

Страница 5: ...e unit where is will be easy to use as shown in the figure below Please use a dedicated fused spur for each hand dryer The hand Dryer must be reliably earthed The bottom of the unit must be at least 150mm above the floor to allow for airflow into the hand dryer The left side of the unit must be at least 150mm away from walls as the power switch is accessed from the left side of the hand dryer Do n...

Страница 6: ...ng 1 Terminate the cable from the hand dryer into the flush mounting wall box 2 Attach the dryer to the wall using the 3 hooks on the mounting panel 3 Secure the dryer to the mounting plate with the fixing screw in the lower right side behind the drip tray The installation screw will not tighten if the lower hook is not completely inserted Ensure the dryer is fixed to the installation panel with t...

Страница 7: ...on or occur the self check indicator pilot light on the right hand side of the display will either light up or flash Alternatively an error code such as E2 may come up on the display If this happens turn off the hand dryer and wait one minute until all the indicators and the display turn off After this time switch the power back on If the indicator is still flashing and or the error code is on the...

Страница 8: ...ccumulated water is standing in the tank for too long a period it will start to smell 1 Pull the tank out in a horizontal direction toward you 2 Open the cover and empty the water from the tank pull the cover in the direction of the arrow on top of the cover and then remove the cover completely 3 Wash out the interior of the drain tray 4 Re install the cover of the drain tray and re attach to the ...

Страница 9: ... located near the LED lights When finished turn power back on The airflow is cold There is a built in heater in the hand dryer Check to see if the heat switch is turned on Check to see if the fuse in the terminal block or inline fuse to the element is blown Check to see if there is any dirt or obstruction on the heater element Check to make sure there is continuity through the element Turn off the...

Страница 10: ...9 Part Names and Dimensions ...

Страница 11: ...and Dryer __________________________________ Date of Manufacture __________________________________ Date of Purchase __________________________________ Environmental Protection Waste electrical products should not be disposed of with household waste please recycle this product where the facilities exist Please check with your local authority For Sales and Service enquiries please contact ATC on th...

Отзывы: