Addendum A: Communication Protocol 

 

Serial Message Protocol Overview—Simple escaped—Version  

The Intelix Simple escaped version serial message protocol can be related to the 
data link layer (layer 2) of the ISO layered communications model. It is a 
connectionless datagram messaging protocol. 
 

Serial Message Fields 

All serial messages, whether they are transmitted to or from an Intelix device, 
use the same message format. Each message contains several distinct fields. 

All 

values are transmitted in hexadecimal format

 

e.g. 0Ah.  

 
Serial Message Fields; Version 3 

Send Message Frame (Simple escaped Protocol) 
 

Protocol Start 

Length 

Data 

1 byte 

1 byte 

0<n<255 bytes 

F1h ##h 

 

 
 
The first field of a message is 

always 

the START byte. The second field is a 1-

byte length. The value of the length field is the number of bytes in the third 
field, the data field. The third field, the data field, holds the parameters of the 
message e.g. Message Class, Message ID, Parameters, etc. 
 
 

Hexadecimal Transmission 

The Intelix Matrix Mixer 

must receive all messages in hexadecimal number 

code

. If messages are transmitted in decimal or ASCII codes, they will fail to 

work. Hexadecimal is a base 16 number code that uses numerals 0-10 and letters 
A,  B,  C,  D,  E,  F.  In  this  document  hex numbers are represented in the form 
“xxh”, where xx are the two hex characters. 

 
 
ASCII values 

When you send commands to an Intelix Device, there is 

one and only one case 

when

 

you use ASCII codes. 

That case is when you send names. Whenever a 

name field appears in an example in this manual, the example is enclosed in 
quotation marks. Any other use of ASCII values will cause the command to fail. 
For example the command 

Set Matrix Mixer Name 

uses as an example name 

field “Emmanuel Lutheran Church”. The quotes indicate that this data should be 
sent as ASCII values. To do this use an ASCII table to obtain the hex value for 
each character, and transmit these values. 

Do NOT transmit the quotation marks 

unless you want the quotation marks included in the Name data written to the 
device. The Quotation marks in the examples are ASCII text delimiters for the 
user of this manual.

 

 
 
Byte Escape Sequence 

The  Simple escaped version message protocol used an “escape byte” sequence 
to insure unambiguous recognition of protocol control bytes (F0 – FFh). If a 
byte in the length, data, or checksum fields falls within the range F0h through 
FFh inclusive, an escape sequence is used to transmit the value. The value is 
translated by sending two bytes: the ESCAPE byte (F0h) itself, followed by the 

Содержание DIGI-HD-8X8

Страница 1: ...DIGI HD 8X8 8 input by 8 output Matrix Switcher...

Страница 2: ...2 www intelix com Table of Contents Overview 4 Installation 5 Operation 7 Troubleshooting and Frequenty Asked Questions 17 Technical Specifications 20 Warranty 21 Contact Information 23 Copyright 200...

Страница 3: ...ety purpose polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third...

Страница 4: ...efinition video and is HDMI 1 3 HDCP compliant Switching is controlled via a diagnostic front panel touch screen or remotely via RS232 IR or Ethernet In addition the DIGI HD 8X8 features eight pass th...

Страница 5: ...owing steps 1 If mounting in a 19 audio video rack affix the 19 rack ears to the DIGI HD 8X8 The DIGI HD 8X8 requires 3 rack units of spacing 2 Power off the source and destination audio and video dev...

Страница 6: ...d separately Ventilation when Rack Mounting At least 2 inches of free air space is required on both sides of the DIGI HD 8X8 for proper side ventilation Ensure there are no closeable doors on the rack...

Страница 7: ...nce IR DIGI HDMI HR R 150 feet 60 feet No DIGI HDMI IR R 150 feet 100 feet Yes 6 Connect the included 12 VDC power supply to the DIGI HD 8X8 7 If controlling remotely connect RS232 Ethernet or IR cont...

Страница 8: ...ut or preset you wish to change 3 If changing a preset scene select the Preset button Select the desired preset 4 If changing output routing select Room View or Matrix View Select the desired output a...

Страница 9: ...Intelix DIGI HD 8X8 Installation Manual www intelix com 9 Touch Screen Flow Diagram note that not all system screens are portrayed...

Страница 10: ...g the DIGI HD 8X8 through the IR sensor on the front panel place an IR emitter directly over the front panel sensor IR Emitter Mounting Tips Surrounding electrical equipment may be producing high leve...

Страница 11: ...hernet cable to a LAN port Within 10 seconds of connecting the DIGI HD 8X8 to the LAN the yellow LED on the matrix s Ethernet port will stop blinking and the green LED will blink intermittently Note T...

Страница 12: ...he desired IR transmit output port 3 Repeat for up to eight devices Note Optionally IR commands for the matrix may be transmitted from a remote receive balun For successful operation the output of the...

Страница 13: ...Intelix DIGI HD 8X8 Installation Manual www intelix com 13 4 All of the remote receive baluns transmit IR commands from the included remote control thereby allowing remote control of the matrix itself...

Страница 14: ...upported Audio Dolby TrueHD 7 1 Dolby TrueHD 5 1 Dolby Digital 5 1 DTS HD Master Audio 7 1 DTS HD Master Audio 5 1 DTS 5 1 PCM 2 0 PCM 5 1 Diagnostic Front panel input to output LEDs Front panel keylo...

Страница 15: ...to work Hexadecimal is a base 16 number code that uses numerals 0 10 and letters A B C D E F In this document hex numbers are represented in the form xxh where xx are the two hex characters ASCII val...

Страница 16: ...cape sequence must fall within the range 00h through 0Fh inclusive any second byte outside of that range indicates that a transmission error has occurred and the Ack byte will not be sent Non escaped...

Страница 17: ...scii character Where CCh is the third character of the Password entry CC should be sent as the hex representation of the ascii character Where DDh is the fourth character of the Password entry DD shou...

Страница 18: ...esponses include 00 for Locked and 01 for Unlocked Reply None Notes None Set Unlock Password ID 8 Description This command is sent to the matrix to change the User password Example F1h 06h 00h 08h AAh...

Страница 19: ...0Ch Reply Lock Status Report Class 0 ID 4 Notes None Set Admin Lock ID 13 Description This command is sent to the matrix to lock the Admin abilities in the matrix Example F1h 02h 00h 0Dh Reply Admin L...

Страница 20: ...ID 5 Notes None Get Input Icon ID 4 Description This command is sent to the matrix to request the current icon for an input Example F1h 03h 01h 04h AAh Where AAh is the input number Reply Input Icon R...

Страница 21: ...e ascii character Reply None Notes Maximum String length is 5 characters A space is transmitted for empty characters Set Output Icon ID 9 Description This command is sent to the matrix to set the Outp...

Страница 22: ...gth Send Input to select then the output to route the input Set All Crosspoints ID 4 Respond with All Crosspoints Status Report ID 6 Description This command is sent to the matrix to set all outputs t...

Страница 23: ...is the preset number Where BBh is the input number that is routed in the preset to output 1 Where CCh is the input number that is routed in the preset to output 2 Where DDh is the input number that i...

Страница 24: ...Where DDh is the third character of the name DDh should be sent as the hex representation of the ascii character Where EEh is the fourth character of the name EEh should be sent as the hex representat...

Страница 25: ...product s serial number or quality control sticker has been removed or defaced or if the product has been altered subjected to damage or abuse repaired by any person not authorized by Intelix to make...

Страница 26: ...ccording to factory specifications a 100 service fee is billed regardless of warranty status All repairs are made in a reasonably quoted amount of time a rush shipment fee of 50 may apply to repairs n...

Страница 27: ...We appreciate your business Please contact us with your questions and comments Intelix 2222 Pleasant View Road Suite 1 Middleton WI 53562 Phone 608 831 0880 Toll Free 866 4 MATMIX Fax 608 831 1833 ww...

Отзывы: