11
8. Close the sensor by inserting the front of the case again and tightening the screw:
1
2
3
5. Troubleshooting
» Perform the walk test by verifying that the entire area you want to protect is being detected by the sensor. If this does not
happen, readjust the PIR and microwave detection sensitivity. To do this, perform the following steps:
1. Remove the front of the case by unscrewing the locking screw;
2. Readjust the PIR and MW sensitivity as desired;
3. If the articulator is being used, make sure that its position allows you to detect the desired area. If necessary, change
the position of the articulator;
4. Reseat the front of the case and perform detection tests;
5. Tighten the locking screw.
Important:
make sure that the microwave is detecting movement only in the desired environment, this is necessary
because the microwave can cross obstacles, such as walls, doors, windows, glass, etc.
» LED Indications
» Green LED: infrared activation.
» Yellow LED: microwave activation.
» Red LED: alarm activation
Note:
when there is a detection, the LED and the Relay were activated for an interval of 3 seconds.
6. Approval
This equipment is not entitled to protection against harmful interference and must not cause interference in duly autho-
rized systems.