background image

11

8. Close the sensor by inserting the front of the case again and tightening the screw:

1

2

3

5. Troubleshooting

 

» Perform the walk test by verifying that the entire area you want to protect is being detected by the sensor. If this does not 

happen, readjust the PIR and microwave detection sensitivity. To do this, perform the following steps: 
1. Remove the front of the case by unscrewing the locking screw; 
2. Readjust the PIR and MW sensitivity as desired;
3. If the articulator is being used, make sure that its position allows you to detect the desired area. If necessary, change 

the position of the articulator;

4. Reseat the front of the case and perform detection tests;
5. Tighten the locking screw.

Important: 

make sure that the microwave is detecting movement only in the desired environment, this is necessary 

because the microwave can cross obstacles, such as walls, doors, windows, glass, etc.

 

 

» LED Indications 

 

» Green LED: infrared activation. 

 

» Yellow LED: microwave activation. 

 

» Red LED: alarm activation 

Note: 

when there is a detection, the LED and the Relay were activated for an interval of 3 seconds.

 

6. Approval

This equipment is not entitled to protection against harmful interference and must not cause interference in duly autho-
rized systems.

Содержание IVP 7001 MW PET

Страница 1: ...User manual IVP 7001 MW PET...

Страница 2: ...duct with Intelbras quality and safety The IVP 7001 MW PET passive infrared sensor has triple technology which combines microwave de tection with detection by passive infrared rays and immunity to ani...

Страница 3: ...ust be installed where a possible intruder is easily detected that is where a person performs movements transverse to the sensor s detection beams when entering the environment The optimal installatio...

Страница 4: ...tall the sensor facing glass doors or windows Make sure the installation location is stable and free from flickering For your security test the product and systems at least once a week This is necessa...

Страница 5: ...Summary 1 Technical specifications 6 2 Product 6 3 Characteristics 7 4 Installation 7 5 Troubleshooting 11 6 Approval 11 Warranty term 12...

Страница 6: ...28 VDC and 100 mA max LED indicators Green PIR Yellow MW and Red Alarm Start Time 60s Relay opening time 5s Operating temperature 10 C 50 C Dimensions W H D 60 120 37 mm The sensor s detection range c...

Страница 7: ...height at which the sensor will be positioned which can vary from 2 to 2 4 m Do not install sensors that have microwave technology close to each other as there may be interference between them Adjustm...

Страница 8: ...al for corner installation 4 Installation without using the articulator Attention if the mounting bracket is inclined with respect to the ground the characteristics of the PET function will change Thi...

Страница 9: ...base and pass the cable as shown in the images 5 Fit the board back into the cabinet as shown below Gire o parafuso no sentido hor rio Insira a placa e deslize a para baixo Insert the card and slide...

Страница 10: ...ode In the AND position both the PIR and the microwave need to detect the presence of an intruder simultaneously to trigger the sensor In the OR position the sensor will trigger if the PIR or microwav...

Страница 11: ...llows you to detect the desired area If necessary change the position of the articulator 4 Reseat the front of the case and perform detection tests 5 Tighten the locking screw Important make sure that...

Страница 12: ...y the Consumer or by third parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the e...

Страница 13: ...te tecnico Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Imported to Brazil by Intelbras S A Ind stria de Telecomunica o Eletr nic...

Отзывы: