7. Perform the configuration on the sensor:

 

» The LED jumper is used to control the LED indication without interfering with the detector. With the switch in the On 

position, the LEDs are enabled to function normally. With the switch in the Off position, the LEDs are disabled, that is, 
they do not light up. Factory default: LEDs On.

LED

Dip

Position

Condition

2

On

LED on.

Off

LED off

 

» P.COUNT: controls the pulse count of the PIR sensor to trigger the alarm. This adjustment has three selectable levels, 

according to the table below. Choose the configuration accordingly according to the environment in which the sensor 
will be installed. Factory Default: 1P

Note: 

Off-Off configuration must not be used.

 

P. COUNT

Dip

Position

Condition

4

5

On - On

1P - Maximum sensitivity

On - Off

2P - Intermediate sensitivity

Off - On

3P - Minimum sensitivity (EMI and RFI)

Greater immunity to false triggering

 

»

 AND / OR function: controls the sensor detection mode. In the AND position, both the PIR and the microwave need 
to detect the presence of an intruder simultaneously to trigger the sensor. In the OR position, the sensor will trigger if 
the PIR or microwave detects it. Factory Default: AND

AND / OR

Dip 

Position

Condition

1

On

AND - PIR and microwave detection for triggering the alarm

Off

OR - PIR or microwave detection for triggering the alarm

 

» The sensor also has a trimpot (MW setting) to adjust the microwave sensitivity. Turning the trimpot clockwise will 

increase the sensitivity, turning it counterclockwise will make the microwave less sensitive. Factory default: MAX 
(maximum sensitivity).

Caution: 

the microwave setting must be at the sensitivity that is able to provide detection only in the protected 

area to avoid undue triggering.

 

Microwaves

Position

Condition

MIN.

Minimum detection range

MAX

Maximum detection range

 

» Relay: controls the state of the relay contact. In the Off position, the contact is normally closed. In the On position, the 

contact is normally open. Factory default: NF (normally closed).

Relay

Dip

Position

Condition

3

On 

NF- Normally closed

Off

NA- Normally open

Содержание IVP 7001 MW PET

Страница 1: ...User manual IVP 7001 MW PET...

Страница 2: ...duct with Intelbras quality and safety The IVP 7001 MW PET passive infrared sensor has triple technology which combines microwave de tection with detection by passive infrared rays and immunity to ani...

Страница 3: ...ust be installed where a possible intruder is easily detected that is where a person performs movements transverse to the sensor s detection beams when entering the environment The optimal installatio...

Страница 4: ...tall the sensor facing glass doors or windows Make sure the installation location is stable and free from flickering For your security test the product and systems at least once a week This is necessa...

Страница 5: ...Summary 1 Technical specifications 6 2 Product 6 3 Characteristics 7 4 Installation 7 5 Troubleshooting 11 6 Approval 11 Warranty term 12...

Страница 6: ...28 VDC and 100 mA max LED indicators Green PIR Yellow MW and Red Alarm Start Time 60s Relay opening time 5s Operating temperature 10 C 50 C Dimensions W H D 60 120 37 mm The sensor s detection range c...

Страница 7: ...height at which the sensor will be positioned which can vary from 2 to 2 4 m Do not install sensors that have microwave technology close to each other as there may be interference between them Adjustm...

Страница 8: ...al for corner installation 4 Installation without using the articulator Attention if the mounting bracket is inclined with respect to the ground the characteristics of the PET function will change Thi...

Страница 9: ...base and pass the cable as shown in the images 5 Fit the board back into the cabinet as shown below Gire o parafuso no sentido hor rio Insira a placa e deslize a para baixo Insert the card and slide...

Страница 10: ...ode In the AND position both the PIR and the microwave need to detect the presence of an intruder simultaneously to trigger the sensor In the OR position the sensor will trigger if the PIR or microwav...

Страница 11: ...llows you to detect the desired area If necessary change the position of the articulator 4 Reseat the front of the case and perform detection tests 5 Tighten the locking screw Important make sure that...

Страница 12: ...y the Consumer or by third parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the e...

Страница 13: ...te tecnico Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Imported to Brazil by Intelbras S A Ind stria de Telecomunica o Eletr nic...

Отзывы: