Intelbras IVP 3000 PET Скачать руководство пользователя страница 7

7

4. Installation

The IVP 3000 PET sensor has the 

PET function.  This function allows the sensor to be immune to false triggering caused by 

small animals and this sensor model is immune to false triggering caused by crawling animals up to 35 kg.

Note: 

it is important to emphasize that the PET function is designed for crawling animals, so if the animal is not on the ground, 

such as on a bench, for example, the animal can be detected thus annulling the PET function, as can be seen in the image below.

Installation

Before starting the installation, it is necessary to define the sensor installation height, which can vary from 2.1 to 2.2 m, 
installation below 2.1 m will compromise the sensor’s 

PET function.

4.1.  Installation without using the articulator

1. Open the sensor through the lock at the bottom;

TRAVA

Lock

2. Loosen the screw that holds the board and slide the board down to remove it; 

Note: 

it is not necessary to remove the screw.

Pa

ra

fuso

3. Tear the seal at the top of the back cover for cable passage;

LACRE

LACRE

Seal

Seal

Содержание IVP 3000 PET

Страница 1: ...User manual IVP 3000 PET...

Страница 2: ...passive infrared sensor offers efficient detection with reduced risk of false triggering caused by the detection of pets The detector will sound the alarm when a person enters the detection area but...

Страница 3: ...to 2 2 m depending on the installation environment Check the installation instructions Do not place objects in front of the sensor To ensure the detection area avoid curtains screens partitions or any...

Страница 4: ...haracteristics 5 2 1 Scan 5 2 2 Detection range 5 2 3 Terminal Block 6 3 Product 6 4 Installation 7 4 1 Installation without using the articulator 7 4 2 Installation without using the articulator 8 5...

Страница 5: ...10 C to 50 C Start Time 60s Relay opening time 6s Alarm output NO NC Tamper switch NC without voltage output 28 Vdc 100 mA Dimensions W H D 65 120 50 mm 2 Characteristics Microcontrolled sensor Sensit...

Страница 6: ...ed 12 V positive feed TAMPER anti tamper switch 3 Product 4 5 6 7 7 11 11 3 11 2 11 1 10 8 9 1 Wire outlet 2 Tamper switch 3 Guidance signal 4 Connection terminals 5 LED indicator 6 Relay 7 Sensor 8 R...

Страница 7: ...can be detected thus annulling the PET function as can be seen in the image below Installation Before starting the installation it is necessary to define the sensor installation height which can vary...

Страница 8: ...e that the back cover is parallel to the wall 6 Snap the board back into the back cover and connect the cables to the terminal block as indicated in the item 2 3 Terminal Block 7 Align the screw that...

Страница 9: ...icated on the side of the back cover Montado na parede Montado no canto da parede Mounted on the corner of the wall Wall mounted 5 Pass the cable through the holes indicated on the articulator 6 Attac...

Страница 10: ...LED on The Pulse jumper controls the pulse count to activate the alarm With the jumper in position 1P the sensor provides maxi mum sensitivity 1P one pulse With the jumper in the 2P position the senso...

Страница 11: ...e sensor will enter operating mode Perform the walk test with movements transverse to the sensor s detection rays observing the LED indications LED Jumper Position Condition Closed ON LED on Open OFF...

Страница 12: ...y the Consumer or by third parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the e...

Страница 13: ...te tecnico Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Imported to Brazil by Intelbras S A Ind stria de Telecomunica o Eletr nic...