12000 Series CLI
True Scale Fabric Switches 12000 Series CLI
Reference Guide
July 2015
82
0:0x00066a00e3002711|DETAIL:transition from DISCOVERING to MASTER
Local LID changed to: 1
Local LID changed to: 1
topology_loopTest: DONE
W|2011/09/15 14:19:28.390U: Thread "esm_top" (0xcca0d828)
MSG:WARNING|SM:Intel 12200 GUID=0x00066a00e30027xx:port 0|COND:#1
Redundancy lost|NODE:Intel 12200 GUID=0x00066a00e3002711:port
0:0x00066a00e3002711|DETAIL:SM redundancy not available
topology_loopTest: DONE
..................done
The SM Loop Test is being started in Fast Mode
Notes
Use this command to start the SM Loop Test in Fast Mode with the specified number of
256-byte packets. Valid values for the number of packets are 0-to-10. The default is
four (that is, if the command is executed without any stated packets, it will start up and
inject 4 packets). If the number of packets is 0, then no packets will be injected. If the
SM has not been previously started, this command will start the SM. Note that the Loop
Test will only function if the SM is in the Master state.
2.5.5.57
smLooptestStop
Stops the SM Loop Test.
Syntax
smLooptestStop
Options
None.
Sample Output
-> XEdge-> smLooptestStop
Waiting for SM to complete shutdownA|2011/09/15 14:21:46.500U: Thread "esm_Start"
(0x85738dd8)
ESM: SM Control: Initiating shutdown of the subnet manager. Some errors and
warnings are common during this process 0
N|2011/09/15 14:21:46.500U: Thread "esm_Start" (0x85738dd8)
MSG:NOTICE|SM:Intel 12200 GUID=0x00066a00e3002711:port 0|COND:#7 SM
shutdown|NODE:Intel 12200 GUID=0x00066a00e3002711:port 0:0x00066a00e3002711
........N|2011/09/15 14:21:54.720U: Thread "INVALID" (0xcca13ac8)
MSG:NOTICE|SM:Intel 12200 GUID=0x00066a00e3002711:port 0|COND:#13 SM state
to inactive|NODE:Intel 12200 GUID=0x00066a00e3002711:port
0:0x00066a00e3002711|DETAIL:transition from MASTER to NOTACTIVE
...A|2011/09/15 14:21:57.720U: Thread "esm_Start" (0x85738dd8)
ESM: SM Control: Subnet manager shutdown complete. 0
...................done
The SM Loop Test is being stopped