True Scale Fabric Switches 12000 Series CLI
July 2015
Reference Guide
Order Number: G91931004US
113
12000 Series CLI
Options
port
–
Port name.
beacon
–
1=on, 0=off
Sample Output
-> ismPortSetBeacon L101 on
Notes
The
port
optoin is case sensitive. Calling this function with only the
portName
option
will only display the current values.
2.5.8.26
ismPortQsfpInfo
Displays information from installed Quad Small Form-factor pluggable (QSFP) cables
Syntax
ismPortQsfpInfo [{all | L<xxx> | L<xxx>P<yy> | Cable<yy>]} [-verbose]
Options
all
- display info for all installed QSFPs in chassis
L<xxx>
- display info for all installed QSFPs on leaf xxx
L<xxx>P<yy>
- display info for QSFP installed on leaf xxx, port yy
Cable<yy>
- display info for QSFP installed on port yy (12300 only)
-verbose
- Verbose output mode
Sample Output
-> ismPortQsfpInfo L101 -verbose
QSFP information may not be available for DDR hybrid cable assemblies. For 0.5 meter
cables, the length may be reported as "1 meter".
2.5.8.27
ismChassisBounce
Bounce enabled ports for an entire chassis.
Syntax
ismChassisBounce
Options
None.
Sample Output
-> ismChassisBounce
2.5.8.28
ismIslBounce
Bounce only the enabled internal ports.