Intel® Storage Server SSR212MC2
Environmental Limits
Revision 1.2
35
8.3 Environmental
Limits
The following table summarizes environmental limits, both operating and non-operating.
Table 21: Operating and Non-Operating Environmental Limits
Temperature Specification
Non-operating
-40 degrees celcius to 70 degrees celcius
Operating Temperature
10 degrees celcius to 35 degrees celcius
Thermal Map
Must not exceed maximum Integrated Circuit (IC) junction temperature as specified
in the component data sheets (CPDs).
Thermal Shock
Specification
Non-operating
-40 degrees celcius to 70 degrees celcius
Humidity
Specification
Non-operating
92% Relative Humidity (RH) at +50 degrees celcius
Vibration Specification
Non-Operating:
2.2 Grms 5-500Hz for the unpackaged and 1.09 Grms 5-500Hz for the
packaged.
Shock Specification
Non-operating
25 G, 11 millisecond (msec)
ESD Specification
Operating
Test (air) to 15 KV and (contact) to 2-8KV with limited errors.
EMI Specification
Operating
Required to meet EMI emission requirements, tested as part of system.