Power Sub-System
Intel® Storage Server SSR212MC2
20 Revision
1.2
2.1.2.1
Power Supply LED Indicator
The power supply module provides a single external bi-color LED to indicate the status of the
power supply. When AC is applied to the Power Supply Unit (PSU) and standby voltages are
available, the LED will blink green. The LED will be solid on green to indicate that all the power
outputs are available. The LED will be solid on amber to indicate that the power supply has
failed, shutdown due to over current, shutdown due to over temperature, or is indicating a
predictive failure. Refer to the following table for conditions of the LED.
Table 13: Power Supply LED Indicators
POWER SUPPLY CONDITION
Power Supply LED
No AC power to all PSU
OFF
No AC power to this PSU only
AMBER
AC present / Only Standby Outputs
On
BLINK GREEN
Power supply Direct Current (DC)
outputs ON and OK
GREEN
Power supply failure (includes over
voltage, over temperature)
AMBER
Voltage Regulator Module (VRM)
failure (cage related)
BLINK GREEN
240VA limit (cage related)
BLINK GREEN
Current limit
AMBER