Replacing the CMOS Battery
Caution: The CMOS battery is NOT hot-swappable. Before removing or replacing the CMOS
battery, you must first take the server out of service, turn off all peripheral devices
connected to the system, turn off the system by pressing the power button, and unplug the
AC power cord from the system or wall outlet.
The lithium battery on the server board powers the RTC in the absence of power. When
the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM
in the RTC (for example, the date and time) may be wrong. For a list of approved devices,
contact your customer service representative or dealer.
Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
Advarsel:
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
Advarsel:
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning:
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
Varoitus:
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
1. Observe the safety and ESD precautions at the beginning of this book. See
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
4. Remove the server's cover and locate the battery. See
5. Pull back gently on the metal tab at the top of the battery.
6. Remove the battery from its socket.
Содержание SR1695GPRX
Страница 4: ...iv Intel Server System SR1695GPRX Service Guide...
Страница 6: ...vi Intel Server System SR1695GPRX Service Guide...
Страница 16: ...xviii Intel Server System SR1695GPRX Service Guide...
Страница 20: ...xxii Intel Server System SR1695GPRX Service Guide...
Страница 33: ...Intel Server System SR1695GPRX Service Guide 13 Server Board Connectors Components...
Страница 38: ...18 Intel Server System SR1695GPRX Service Guide...
Страница 75: ...Intel Server System SR1695GPRX Service Guide 55 Figure 38 Installing the backplane board EP0015 A B C...
Страница 85: ...EP0018 EP0026 Intel Server System SR1695GPRX Service Guide 65 Figure 46 Replacing the Rotor Fan...
Страница 102: ...82 Intel Server System SR1695GPRX Service Guide...
Страница 136: ...116 Intel Server System SR1695GPRX Service Guide Intel Intel Intel Web UL...
Страница 137: ...Intel Server System SR1695GPRX Service Guide 117 ITE ITE 5V...
Страница 138: ...118 Intel Server System SR1695GPRX Service Guide...
Страница 139: ...Intel Server System SR1695GPRX Service Guide 119 ESD ESD ESD ESD ESD...
Страница 140: ...120 Intel Server System SR1695GPRX Service Guide...
Страница 154: ...134 Intel Server System SR1695GPRX Service Guide...
Страница 158: ...138 Intel Server System SR1695GPRX Service Guide...
Страница 162: ...142 Intel Server System SR1695GPRX Service Guide...