6
Server System SR1695GPRX Service Guide
NOTE:
Blink rate is ~ 1Hz at 50% duty cycle.
Table 5. System Status LED Operation
S0
ACPI
Solid on
System and the operating system are up and running.
State
Power Mode
LED
Description
LED
Color
State
Description
Off
N/A
Not ready
Power off or BMC initialization completes if no degraded,
non-critical, critical, or non-recoverable conditions exist
after power cable plug in.
Green/Amber
Both solid on
Not ready
Pre DC Power On – 15-20 second BMC Initialization when
AC is applied to the server. The system will not POST until
BMC initialization completes.
Green
Solid on
Ok
System ready.
Blink
Degraded
BIOS detected:
1. Unable to use all of the installed memory (more than
one DIMM installed).
2. In a mirrored configuration, when memory mirroring
takes place and system loses memory redundancy.
This is not covered by (2).
3. PCI Express* correctable link errors.
Integrated BMC detected
1. Redundancy loss such as a power supply or fan.
Applies only if the associated platform subsystem
has redundancy capabilities.
2. CPU disabled – if there are two CPUs and one CPU
is disabled.
3. Fan alarm – Fan failure. Number of operational fans
should be more than minimum number needed to
cool the system.
4. Non-critical threshold crossed – Temperature,
voltage, power nozzle, power gauge, and
PROCHOT2 (Therm Ctrl) sensors.
5. Battery failure.
6. Predictive failure when the system has redundant
power supplies.
Содержание SR1695GPRX
Страница 4: ...iv Intel Server System SR1695GPRX Service Guide...
Страница 6: ...vi Intel Server System SR1695GPRX Service Guide...
Страница 16: ...xviii Intel Server System SR1695GPRX Service Guide...
Страница 20: ...xxii Intel Server System SR1695GPRX Service Guide...
Страница 33: ...Intel Server System SR1695GPRX Service Guide 13 Server Board Connectors Components...
Страница 38: ...18 Intel Server System SR1695GPRX Service Guide...
Страница 75: ...Intel Server System SR1695GPRX Service Guide 55 Figure 38 Installing the backplane board EP0015 A B C...
Страница 85: ...EP0018 EP0026 Intel Server System SR1695GPRX Service Guide 65 Figure 46 Replacing the Rotor Fan...
Страница 102: ...82 Intel Server System SR1695GPRX Service Guide...
Страница 136: ...116 Intel Server System SR1695GPRX Service Guide Intel Intel Intel Web UL...
Страница 137: ...Intel Server System SR1695GPRX Service Guide 117 ITE ITE 5V...
Страница 138: ...118 Intel Server System SR1695GPRX Service Guide...
Страница 139: ...Intel Server System SR1695GPRX Service Guide 119 ESD ESD ESD ESD ESD...
Страница 140: ...120 Intel Server System SR1695GPRX Service Guide...
Страница 154: ...134 Intel Server System SR1695GPRX Service Guide...
Страница 158: ...138 Intel Server System SR1695GPRX Service Guide...
Страница 162: ...142 Intel Server System SR1695GPRX Service Guide...