88
Intel
®
Server System SR1530CL / SR1530HCL / SR1530HCLS
7. Turn the bracket over and remove the two screws that attach the failed fan to the fan
bracket. Save these screws. You will reinstall them later. See letter “A” in the
following figure). Lift the fan from the bracket (see letter “B”).
Figure 89. Removing System Fan from Fan Bracket (SR1530CL)
8. Install the replacement fan onto the fan bracket, using the two screws you removed
previously.
9. Set the fan assembly into the system. Insert the rear edge first and push the
assembly slightly rearward to clear the hard disk drive brackets. Use caution to
make sure you do not pinch any cables.
10. Route the cable from the fan at the right around the right side of the assembly and
under the clip at the front of the fan bracket.
11. Secure the fan assembly to the system using the two screws you removed
previously.
AF000992