background image

ii

Warning

 

Read all caution and safety 

 

statements in this document 

 

before performing any of the 

instructions.  Also see the 

Intel

®

 

Server Board and Server Chassis 

Safety Information

 document at:

http://www.intel.com/support/

motherboards/server/sb/cs-010770

.htm

 

for complete safety information.

Warning

           Installation and service

           of this product to be

           performed only by

qualified service personnel

to avoid risk of injury from

electrical shock or energy

hazard.

Caution

 

Observe normal ESD

            [Electrostatic Discharge]

            procedures during system

integration to avoid possible

damage to server board and/or

other components.

Tools Required

        Anti-static

wrist strap

     Phillips*

screwdriver

Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.  *Other names and brands may be claimed as the 

property of others.  Copyright © 2012, Intel Corporation. All rights reserved.

Thermal Operation and Configuration Requirements

To keep the system operating within supported maximum thermal limits, the system must meet the following operating and 
configuration guidelines:

• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time.  
Doing so may affect long term reliability of the system.

• The CPU-1 pro CPU heatsink must be installed first.  

• 

Memory Slot population requirements:

NOTE: Specified memory slots either can be populated with a DIMM or supplied DIMM Blank (DIMM blanks are only
provided in systems that require them). Memory  population rules apply when installing DIMMs.
      

▪ 

DIMM Population Rules on CPU-1

 

         Install DIMMs in order; Channels A, B, and C. Start with 1st DIMM slot (blue) on each channel, then 2nd slot.

     ▪ 

DIMM Population Rules on CPU-2 

        

Install DIMMs in order; Channels D, E, and F. Start with 1st DIMM slot (blue) on each channel, then 2nd slot.

• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive 
blank.

• The air duct must be installed at all times.

• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all 
times.

• The system top-cover must be installed at all times.

Содержание R2000SC

Страница 1: ...ts If you are not familiar with ESD Electrostatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other supporting do...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...sor Heatsink s 3 Install Memory Modules 4 Install Hard Drives 5 Install Optical Drive 6 Install the Air Duct 6 Install Add in Card 7 Install Rack Handles 7 Install Intel RAID C600 Upgrade Key optional...

Страница 4: ...supported maximum thermal limits the system must meet the following operating and configuration guidelines Ambient in let temperature cannot exceed 35 C and should not remain at this maximum level for...

Страница 5: ...Swap Hard Drive Bays System Fans CPU1 CPU2 1 1 Redundant Power Supply Modules Server Board Air Duct Optical Drive Bay Optional Front Control Panel Useful Information The system must be configured with...

Страница 6: ...or disconnected or loose cables and components that may have occurred during shipping 2 Remove the Top Cover B Remove the four screws A A B B Slide the cover backward and lift up 3 Remove the Air Duct...

Страница 7: ...e the Processor Protective Cover A A Take the processor out of the box and remove the protective shipping cover A Open the Socket Lever 1 When opening a socket DO NOT TOUCH the gold socket wires 2 Whe...

Страница 8: ...slot Install Memory Modules Continued Memory Con gurations and Population Order Intel Server Board S2400SC For best performance a minimum of three DIMMs per CPU is recommended populated in the blue s...

Страница 9: ...k off the tab on the plastic drive blank Install 2 5 Hard Drive as option Secure the hard disk drive using the four screws for 2 5 HDD 3 5 H D D D D Install the hard disk drive using the same four scr...

Страница 10: ...C Connect the cables as shown O p t i c a l D e v i c e A s s e m b l y B Data Power Optical Drive C 11 Install Add in Card A Remove the screw B Slide the retention device and lift upward A A B Insta...

Страница 11: ...el RMM4 NIC Install Intel RMM4 Lite A Remove the filler Panel and Retention Device refer to STEP 11 B Connect one end of the flex cable to the RMM4 connector on the RMM4 NIC module C Attach the RMM4 m...

Страница 12: ...ce the top cover on system and slide towards the front of the chassis until the recessed front edge is fully engaged Install the three screws at the front and torque to 7 9in lbs Then install the scre...

Страница 13: ...he BIOS setup See the Intel Server Board S2400SC Technical Product Specification for more information Use the instructions provided with the RAID controller and with the operating system With the oper...

Страница 14: ...nt control panel types The features of each are as follows A ID Button with integrated LED B NMI Button C LAN 1 Activity LED D LAN 3 Activity LED E System Cold Reset Button F System Status LED G Power...

Страница 15: ...VGA SerialA SYS FAN_7 CPU 2 Power CPU 2 Fan CPU 1 Power Slot 2 PCI 32 Slot 3 PCI e Gen 2 Slot 4 PCI e Gen 3 Slot 5 PCI e Gen 3 Slot 6 PCI e Gen 3 Front Panel RMM4 NIC Storage Upgrade Key CPU 1 Fan SY...

Страница 16: ...12 Reference System Cabling Diagram R2308SC2SHFN Power Supply One 600w Fixed FAN 1 FAN 2 FAN 3 8 x 3 5 HSBP 0 3 4 7 Optical Drive Front Panel Front Panel USB I2 C...

Страница 17: ...13 Reference System Cabling Diagram R2308SC2SHDR FAN 1 FAN 2 FAN 3 8 x 3 5 HSBP 0 3 4 7 Optical Drive Front Panel Front Panel USB I2 C Power Supply Two 460w CRPS PDB...

Страница 18: ...14 Reference System Cabling Diagram R2312SC2SHGR 12 x 3 5 HSBP Interposer Board FAN 1 FAN 2 FAN 3 Front Panel I2 C Power Supply Two 750w CRPS PDB...

Страница 19: ...This page is intentionally left blank...

Страница 20: ...G71872 002...