Intel® Server D50TNP Family Integration and Service Guide
29
Figure 10. Processor Components and Processor Socket Reference Diagram with Standard Heat Sink
To properly assemble the PHM and install it onto the server board, the procedures described in the following
sections must be followed in the order specified. These instructions assume that all the PHM components
are new and the Thermal Interface Material (TIM) is already applied to the bottom of the heat sink.
2.3.1.1
Processor Heat Sink Module (PHM) Assembly
Caution:
Full ESD precautions should be followed to perform reassembly of the PHM and reinstallation of
the PHM to the server board. At no time should the processor itself be handled.
Each component within the PHM assembly includes a Pin 1 indicator. Pin 1 indicator alignment between all
components is required throughout the assembly process.