Intel® Server D50TNP Family Integration and Service Guide
142
7.7
M.2 Storage Devices Replacement
This procedure applies to M.2 storage replacement for both 1U and 2U riser assemblies with illustrations
showing differences where applicable.
Required Tools and Supplies:
•
Anti-static wrist strap and conductive foam pad (recommended)
•
Phillips* head screwdriver #1
7.7.1
M.2 and Heat Sink Replacement for Air-Cooled Configurations
Remove the riser assembly that the M.2 SSD is attached to (see
Section 7.8)
.
Figure 197. Removing Air-Cooled M.2 Heat Sink
1.
Locate the heat sink on the left side of the riser assembly and remove the screw (see Letter A).
2.
Slide the heat sink in the direction shown to remove it (see Letter B).
Figure 198. Removing Air-Cooled M.2 SSD
3.
Remove the screw from the M.2 mounting standoff on the left side of the riser assembly (see Letter A).
4.
Carefully rotate outward the free end of the M.2 SSD away from the riser assembly (see Letter B
).
5.
Grasp the M.2 SSD by its edges and gently remove it from the connector in the direction shown
(see Letter C).
1U Riser Assembly
2U Riser Assembly
1U Riser Assembly
2U Riser Assembly