Intel® Server D50TNP Family Integration and Service Guide
144
7.7.2
M.2 SSD and Cold Plate Replacement for Liquid-Cooled Configurations
Remove the riser assembly that the M.2 SSD is attached to (see
Section 7.8)
.
Due to the mechanical differences between the air-cooled and liquid-cooled configurations, the M.2 SSD
cold plate is used to absorb the heat generated by the SSD in a liquid-cooled configuration instead of a heat
sink. If the new M.2 SSD has 110 mm form factor, it requires the installation of Thermal Interface Material
(TIM) (BERGQUIST
™
TGP 1000VOUS) on the rear side of the M.2 SSD.
Figure 201. Removing the Liquid-Cooled M.2 Cold Plate
1.
Locate the cold plate on the left side of the riser assembly and remove the screw (see Letter A).
2.
Slide the cold plate in the direction shown to remove it (see Letter C).
Figure 202. Removing liquid-Cooled M.2 SSD
3.
Remove the screw from the M.2 mounting standoff on the left side of the riser assembly (see Letter A).
4.
Carefully rotate outward the free end of the M.2 SSD away from the riser assembly (see Letter B
).
5.
Grasp the M.2 SSD by its edges and gently remove it from the connector in the direction shown
(see Letter C).