PECI Interface
56
Thermal/Mechanical Specifications and Design Guide
7.1.2.2
GetDIB()
The processor PECI client implementation of GetDIB() includes an 8-byte response and
provides information regarding client revision number and the number of supported
domains. All processor PECI clients support the GetDIB() command.
7.1.2.2.1
Command Format
The GetDIB() format is as follows:
Write Length:
0x01
Read Length:
0x08
Command:
0xF7
7.1.2.2.2
Device Info
The Device Info byte gives details regarding the PECI client configuration. At a
minimum, all clients supporting GetDIB will return the number of domains inside the
package using this field. With any client, at least one domain (Domain 0) must exist.
Therefore, the Number of Domains reported is defined as the number of domains in
addition to Domain 0. For example, if bit 2 of the Device Info byte returns a ‘1’, that
would indicate that the PECI client supports two domains.
Figure 7-3. GetDIB()
Byte #
Byte
Definition
0
Client Address
1
Write Length
0x01
2
Read Length
0x08
4
FCS
3
Cmd Code
0xf7
5
Device Info
6
Revision
Number
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
FCS
Figure 7-4. Device Info Field Definition
Reserved
# of Domains
Reserved
7 6 5 4 3 2 1 0
Byte# 5
Содержание BX80619I73820
Страница 10: ...10 Thermal Mechanical Specifications and Design Guide...
Страница 14: ...Introduction 14 Thermal Mechanical Specifications and Design Guide...
Страница 104: ...Thermal Solutions 104 Thermal Mechanical Specifications and Design Guide...
Страница 112: ...Mechanical Drawings 112 Thermal Mechanical Specifications and Design Guide...
Страница 118: ...Socket Mechanical Drawings 118 Thermal Mechanical Specifications and Design Guide...
Страница 124: ...Package Mechanical Drawings 124 Thermal Mechanical Specifications and Design Guide...