![Intel 480T Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/intel/480t/480t_user-manual_2073446032.webp)
30
C H A P T E R 2
Installation and Setup
When deciding where to install the switch, ensure that:
•
The switch is accessible and cables can be connected easily.
•
Water or moisture cannot enter the case of the unit.
•
Air-flow around the unit and through the vents in the side of the
case is not restricted. You should provide a minimum of 25mm (1-
inch) clearance.
•
No objects are placed on top of the unit.
•
Units are not stacked more than four high if the switch is free-
standing.
Installing the Switch
The switch can be mounted in a rack, or placed free-standing on a
tabletop.
Rack Mounting
Caution
The rack mount kits must not be used to suspend the
switch from under a table or desk, or to attach it to a
wall.
To rack mount the switch:
1
Place the switch the right way up on a hard flat surface, with
the front facing you.
2
Remove the existing screws from the sides of the chassis and
retain for Step 4.
3
Locate a mounting bracket over the mounting holes on one
side of the unit.
4
Insert the screws and fully tighten with a screwdriver, as
shown in Figure 3.
Содержание 480T
Страница 16: ...14 P R E F A C E...
Страница 88: ...86 C H A P T E R 4 Configuring Switch Ports...
Страница 112: ...110 C H A P T E R 5 Virtual LANs VLANs...
Страница 152: ...150 C H A P T E R 8 Quality of Service QoS...
Страница 166: ...164 C H A P T E R 9 Enterprise Standby Router Protocol...
Страница 198: ...196 C H A P T E R 1 0 IP Unicast Routing...
Страница 228: ...226 C H A P T E R 1 1 RIP and OSPF...
Страница 254: ...252 C H A P T E R 1 3 IPX Routing...
Страница 274: ...272 C H A P T E R 1 4 Access Policies...
Страница 296: ...294 C H A P T E R 1 6 Using Web Device Manager...
Страница 320: ...318 A P P E N D I X A...
Страница 328: ...326 A P P E N D I X B...
Страница 346: ...344 A P P E N D I X C...
Страница 358: ...356 I N D E X...
Страница 366: ...364 I N D E X...