9
3. System startup procedure
1. Turn on the handset by pressing the power button for 2 sec-
onds
2. Turn the Key switch on your locomotive to ON. Position.
3. The CC 50A will go through a startup sequence.
4. When all system checks are done and turn out OK, it will start
flashing the system LED indicator while the Master Relay led will
become lit solid
5. press the brake button on the handset until the system LED
lights up solid .
Startup Error Messages:
These error messages appear if any of the system checks at startup return a
negative result.
The controller will check for battery voltage and motor drive/motor health, before
it unlocks the system for use
Low locomotive battery error:
Symptom:
Solution:
Battery voltage shows 0 Check the wire and fuse for battery monitor 2
Battery voltage is ~ 18.0V Locomotive batteries need recharged.
Motor test failed error:
Symptom:
Solution:
Motor short detected!
Check the wiring of the motors for shorts.
Check the motors directly for shorts.
Startup:
1.
2.
3.
4.
5.
initially off
flashing solid
press
Both LEDs solid
LOCO BATTERY LOW
Low Battery Voltage: 0.02V
MOTOR TEST FAILED
Motor short detected!
FWD>
0.0
FWD>
0.0
Locomotive battery shows up.
Содержание CC 50 A
Страница 1: ...Critter Control Model CC 50 A User Manual...
Страница 22: ...22 Horn installation variants...
Страница 24: ...24 Brake controller installation diagram BC100 Brake controller installation diagram BC50...
Страница 25: ...25 Combo controller installation diagram BHC100...
Страница 27: ...27 Notes...
Страница 28: ...28 9 Wiring Diagram...
Страница 29: ...29...
Страница 30: ...30 Notes...
Страница 31: ...31...
Страница 32: ...2016 Integral Circuits LLC...