DGC3

PolyGard

® 

Digital Gas Controller

User Manual - DGC3

Page 22

4 Notes and General Information 

It is important to read this user manual carefully in order to understand the information and instructions.  The 

PolyGard

®

 DGC3 gas monitoring, control and alarm system may only be used for applications in accordance to the 

intended use.  The appropriate operating and maintenance instructions and recommendations must be followed. 
Due to permanent product developments, MSR reserves the right to change specifications without notice.  The 

information contained herein is based on data considered to be accurate.  However, no guarantee or warranty is 

expressed or implied concerning the accuracy of these data. 

4.1 

Intended Product Application 

The PolyGard

®

 DGC3 is designed and manufactured for controlling, for saving energy and keeping OSHA air 

quality in commercial buildings and manufacturing plants (i.e. detection and automatic exhaust fan control for 

automotive maintenance facilities, enclosed parking garages, engine repair shops, warehouses with forklifts, fire 

stations, tunnels, etc.). 

4.2 

Installers’ Responsibilities 

It is the installer’s responsibility to ensure that all PolyGard

®

 DGC3 are installed in compliance with all national and 

local regulations and OSHA requirements.  All installations should be executed only by technicians familiar with 

proper installation techniques, the codes, standards and proper safety procedures for control installations, as well 

as the latest edition of the National Electrical Code (ANSI/NFPA70).  It is also essential to strictly follow all 

instructions as provided in this user manual. 

4.3 Maintenance 

It is recommended to check the PolyGard

®

 DGC3 system regularly.  With regular maintenance deviancies in 

efficiency can easily be corrected.  

4.4 

Limited Warranty 

MSR-Electronic-GmbH and IN

TEC

 Controls warrants the PolyGard

®

 DGC3 for a period of two years from the date 

of shipment against defects in material or workmanship. Should any evidence of defects in material or workmanship 

occur during the warranty period, IN

TEC

 Controls will repair or replace the product at their own discretion, without 

charge.
This warranty does not apply to units that have been altered, had attempted repair, or been subject to abuse, 

accidental or otherwise. The above warranty is in lieu of all other express warranties, obligations or liabilities.
This warranty applies only to the PolyGard

®

 DGC3. MSR-Electronic-GmbH and/or IN

TEC

 Controls shall not be 

liable for any incidental or consequential damages arising out of or related to the use of the PolyGard

®

 DGC3.

If the PolyGard

®

 DGC3 needs to be returned to IN

TEC

 Controls for service, an RMA number must be obtained prior 

to sending.

Specifications subject to change without notice. | USA 130917 | Page 22 of 22

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

DGC3 – UserManual

Polygard® is a registered trademark of MSR | DGC3

Specifications subject to change without notice. | USA 160104 | Page 22 of 22

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

DGC3 – UserManual

PolyGard

®

 is a registered trademark of MSR-Electronic GmbH | DGC3

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Specifications subject to change without notice. | USA 200211 | Page 22 of 22

DGC3 – UserManual

Содержание PolyGard DGC3

Страница 1: ...ual July 2011 Specifications subject to change without notice USA 130917 Page 1 of 22 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 7887 888 GO INTEC relevantsolutions com inteccontrols DGC3 U...

Страница 2: ...Mode 17 3 6 8 MP Fault Assigned to Alarm 17 3 6 9 Alarm Assigned to Alarm Relay 17 3 6 10 MP Signal Assigned to Analog Output 17 3 7 Menu System Parameters 18 3 7 1 Service Mode 19 3 7 2 Software Vers...

Страница 3: ...nd alarm threshold enable a very flexible use in the gas measuring technique Simple and comfortable commissioning is possible thanks to the configuration with preset parameters Configuration parameter...

Страница 4: ...ne relay is manually operated LED yellow Flashes at system or sensor failure or when maintenance needed LED green Power LED 2 2 Setting Changing Parameters or Set points Open desired menu window Code...

Страница 5: ...evels Starting menu Scrolling of the measuring points of all registered transmitters in 10 second intervals Main menu Submenu 1 and 2 Starting menu Main menu Submenu Display and reset of errors See fr...

Страница 6: ...fault is only possible after having removed the cause Select menu System Errors Example Communication error MP 01 1 Reset the fault Fault reset or Fault reset Cause not eliminated Reset not possible 3...

Страница 7: ...itter not calibrated defective Solution Check cable to AT transmitter perform calibration replace AT transmitter GC Error Internal communication error I O Board to LCD Board Cause Internal error Solut...

Страница 8: ...the orange red alarm LED at the Gas Controller is lit continuously The external operation of the alarm relay via an assigned digital input has priority to the manual operation in the menu Status Relay...

Страница 9: ...value of the analog transmitter Display for software version 16 bus transmitters Display for software version 8 bus transmitters and 8 analog transmitters Symbol Description Default Function MP 01 1 M...

Страница 10: ...t time for switch OFF delay See 3 5 6 Relay Mode De energized Static Flash 0 s Relay Parameter R 01 Latching Mode No Time Quitt DI 0s 0 0 External Mode DI ON 0 OFF 0 Delay ON Time 0 s Delay OFF Time 0...

Страница 11: ...ing mode active Acknowledging a latching relay in the menu Status Relay is only possible if the gas concentration is again lower than the alarm threshold including hysteresis In this case the status l...

Страница 12: ...set of the relay by push button after time having run out and when alarm is still acting relay is set again Response function Time 120 Time for automatic reset function or response function 0 no reset...

Страница 13: ...0 Mode OFF Relay is only deactivated at the end of the defined time sec 0 sec No delay 3 6 Menu MP Parameters Display and change of MP parameters including activation of measuring points and assignme...

Страница 14: ...10 Measuring range 300 ppm MP Signal Linear Threshold 1 80 ppm Threshold 2 100 ppm Threshold 3 120 ppm Threshold 4 120 ppm Hysteresis 15 ppm Delay time ON 0 s Delay time OFF 0 s C A Mode CV Alarm 1 2...

Страница 15: ...lorine Hydrogen sulphide Sulphur dioxide Carbon dioxide5 Oxygen falling 3 Ammonia Nitrogen dioxide Nitrogen oxide Combustible gas ppm Vol ppm ppm ppk r F C ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm...

Страница 16: ...efined with full scale value in order to avoid false alarms For O2 measurement Pay attention to the alarm activation at decreasing or increasing concentration Symbol Description Default Status Functio...

Страница 17: ...P 01 Measuring Point Selection of MP No 1 A1 A2 A3 A4 01 02 03 00 01 Alarm 1 activates alarm relay R 01 02 Alarm 2 activates alarm relay R 02 03 Alarm 3 activates alarm relay R 03 04 Alarm 4 doesn t a...

Страница 18: ...0 AV Overlay 120 s 120 ppm AV Time 1800 s Maintenance interval Days 365 Customer Pass Change Failure Relay XX Power On Time 30 s EP Module 1 Inactive EP Module 2 Inactive Specifications subject to cha...

Страница 19: ...e days counter reaches zero the failure signal is activated the following morning at 9 o clock and the phone no of the service technician occurs in the display The remaining days until the next mainte...

Страница 20: ...ring point sends the signal as defined in the menu C A Mode CV or AV Out of the signals of all assigned measuring points the Gas Controller module determines the minimum the maximum or the average val...

Страница 21: ...on of the EP 05 modules a module address is assigned to each module by the address selector See table The table shows the assignment of the relay numbers to the individual modules Symbol Description D...

Страница 22: ...latest edition of the National Electrical Code ANSI NFPA70 It is also essential to strictly follow all instructions as provided in this user manual 4 3 Maintenance It is recommended to check the PolyG...

Отзывы: