9 Technical Data
General sensor performances
Gas type
Oxygen (O
2
)
Sensor element
Electrochemical, diffusion
Measuring range
0 – 25 vol. %
Temperature range
-4°F to 122°F (-20°C to 50°C)
Pressure range
Atmosphere ± 15 %
Humidity
0 – 99 % RH non condensing
Storage temperature range
23°F to 86°F (-5°C to 30°C)
Storage time
Max. 6 months
Mounting height
1.5 to 1.8 m (5 to 6 ft.)
Accuracy
± 0.1 vol. %
Long-term output drift
< 5% signal loss/year
Response time
t
90
< 15 sec.
Life expectancy
2 years/normal operating environment
Cross sensitivity
1
Concentration (ppm)
Reaction (vol. %O
2
)
Carbon dioxide, CO
2
5 vol. %
2
Electrical
Power supply
18 - 28 VDC/AC, reverse polarity protected
(2-wire mode only VDC)
Power consumption (without options)
- Analog mode
- Bus mode
22 mA, max. (0.6 VA)
12 mA, max. (0.3 VA)
Output signal
Analog output signal
Selectable: Current / tension
Starting point 0 / 20 %
(0) 4 – 20 mA, load
≤
500
Ω
,
(0) 2 - 10 V; load ≥ 50 k
Ω
proportional, overload and short-circuit proof
Physical
Enclosure
2
Stainless steel V2A
Enclosure colour
2
Natural, brushed
Dimensions
2
(H x W x D)
113 x 135 x 45 mm /(5.35 x 4.5 x 1.8 in.)
Weight
2
Approx. 0,5 kg (1.1 Ibs.)
Protection class
2
IP 55
Mounting
2
Wall mounting, pillar mounting
Cable entry
Standard 1 x M 20
Wire connection
Screw-type terminal min. 0.25 to. 2.5 mm
2
24 to 14 AWG
Wire distance (analog mode)
Current signal ca. 500 m (1500 ft.)
Voltage signal ca. 200 m (600 ft.)
1
The table doesn’t claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned
cross sensitivity data are only reference values valid for new sensors.
2
Indications only for option "stainless steel", for further types see datasheet “AT-DT Enclosure”.
Specifications subject to change without notice. | USA 150109 | Page 9 of 13
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
AT-1195_V3 – UserManual
Polygard® is a registered trademark of MSR | AT-1195_V3_UserManual
Specifications subject to change without notice. | USA 160104 | Page 9 of 13
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
AT-1195 V3 – UserManual
PolyGard
®
is a registered trademark of MSR-Electronic GmbH | AT-1195_V3_UserManual
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 200211 | Page 9 of 13
AT-1195 V3 – UserManual