SECTION 5
-
Electrical & Wiring instructions
PO
WE
R
WIRING TO THE CONTROLLER
ISOLATE THE ELECTRIC SUPPLY
TO THE HIU!
•
The Controller front cover is fixed by 4 screws
at each corner
•
Remove the cover and locate the terminals as
pictured
-
spare terminals marked AUX
•
Connect the pre
-
wired cable (NO VOLTAGE)
as connected to the relay on terminals 5 and
9.
•
If the billing system is VOLT FREE then the
relay is not required—check with the billing
provider
•
Replace the cover.
Installation complete.
PUMP
DIVERTER
PROGRAMMABLE
ROOM
THERMOSTAT
LP SWITCH
PICV
RELAY
240V signal from
‘
Prepayment
’
monitor.
AUX
SWITCH
Hiper HIU Controller
RELAY NOT REQUIRED
WHEN THE BILLING
SYSTEM IS VOLT FREE
09/17 E & OE
Now programme the controller for
‘
Pre
-
Payment
’
ON
-
see separate document;
‘
Installer Level Settings
’
(not to be left with the end user)