background image

Inhalt 

4

 

 

 

 

 

 

 

 

 

 

 

 

Sep-06

 

3.4

 

S

WITCH THE 

D

EVICE ON AND 

T

EST IT

...........................................22

 

3.5

 

I

NITIAL 

C

ONFIGURATION

...........................................................23

 

3.5.1

 

Initial configuration via HSComm GSM........................................... 23

 

3.5.2

 

Initial configuration with AT commands......................................... 26

 

3.6

 

R

ESTART

.................................................................................27

 

3.6.1

 

Procedure: Insert SIM card ............................................................... 27

 

3.7

 

C

ONNECTION 

T

EST

...................................................................28

 

3.8

 

C

AUSES OF 

E

RROR DURING 

I

MPLEMENTATION

...............................29

 

3.9

 

T

ESTING THE 

S

IGNAL 

Q

UALITY

....................................................30

 

3.10

 

C

HECKING THE 

PIN

 AND THE 

L

OGIN 

S

TATE

...................................31

 

4

 

OPERATING MODES ................................................. 33

 

4.1

 

C

ONNECTION MODE 

(

ONLINE

) ....................................................33

 

4.2

 

C

OMMAND 

M

ODE

...................................................................34

 

4.2.1

 

Offline command mode ................................................................... 34

 

4.2.2

 

Online command mode (local)......................................................... 34

 

4.2.3

 

Remote configuration...................................................................... 35

 

4.2.4

 

SMS configuration............................................................................ 35

 

4.3

 

A

LARM 

S

TATE

.........................................................................35

 

4.4

 

AT

 

C

OMMANDS FOR 

S

WITCHING INTO ANOTHER 

O

PERATING 

M

ODE

36

 

5

 

CONFIGURATION SOFTWARE HSCOMM GSM ......... 37

 

5.1

 

H

ELP

......................................................................................37

 

5.2

 

HSC

OMM 

U

SER 

I

NTERFACE

.......................................................38

 

5.2.1

 

Menus............................................................................................... 38

 

5.2.2

 

Buttons ............................................................................................. 40

 

5.2.3

 

Status bar ......................................................................................... 41

 

5.2.4

 

Tabs .................................................................................................. 41

 

Содержание GSM 4.2 Compact

Страница 1: ...Manual INSYS GSM 4 2 INSYS GSM 4 2 compact Sep 06...

Страница 2: ...t information and their consequences Suggestions for improvements and comments are gladly accepted Trademarks The use of a trademark not shown below is not an indication that it is freely available fo...

Страница 3: ...ics 13 2 5 2 Power supply 14 2 5 3 Serial interface RS232 V 24 15 2 5 4 SIM card 15 2 5 5 Audio interface not for INSYS GSM 4 2 compact 16 2 5 6 Antenna interface 16 2 5 7 Digital inputs and outputs 1...

Страница 4: ...3 9 TESTING THE SIGNAL QUALITY 30 3 10 CHECKING THE PIN AND THE LOGIN STATE 31 4 OPERATING MODES 33 4 1 CONNECTION MODE ONLINE 33 4 2 COMMAND MODE 34 4 2 1 Offline command mode 34 4 2 2 Online command...

Страница 5: ...53 6 1 10 DTR behavior 53 6 2 SMS 55 6 2 1 Requirements for receiving an SMS 55 6 2 2 Receiving SMS 55 6 2 3 Automatic SMS processing 56 6 2 4 Commands via SMS 57 6 2 5 SMS acknowledgement 58 6 2 6 Re...

Страница 6: ...er 74 6 5 2 Passwords and DTMF PIN 75 6 5 3 Security callback 76 6 6 HISTORY 78 6 7 AUDIO INTERFACE AND VOICE CONNECTIONS 80 6 8 FLASH UPDATE 80 6 9 OPERATION WITH PLCS 82 7 AT COMMAND SETS 84 7 1 SHO...

Страница 7: ...mage The warnings and cautions are described as follows Caution Damage of components Not observing this note may result in destruction of the device Warning Not observing this warning may result in ma...

Страница 8: ...or small letters The command is processed after the modem received a CR input In the following the used syntax is described using two examples AT CPIN n Entering the PIN 1234 at cpin 1234 OK ATD ip po...

Страница 9: ...EE guidelines the taking back and recycling of legacy systems for our clients is regulated as follows Please send those legacy systems to the following address carriage prepaid Frankenberg Metalle G r...

Страница 10: ...Fields of application The INSYS GMS offers several options for transmitting data via the GSM network You may use it to implement data connections or for example a messaging system with pre configured...

Страница 11: ...INSYS GSM 4 2 INSYS GSM 4 2 compact Overview Sep 06 11 2 1 INSYS GSM 4 2 2 2 INSYS GSM 4 2 compact...

Страница 12: ...s designed for the system environment of mobile networks with 900 MHz and 1800 MHz according to ETSI GSM phase 2 2 Accessing a GSM network requires a SIM card of a network provider The data connection...

Страница 13: ...ed command set Via SMS only extended command set Alarm input Usage as alarm or pulse input with 10 different pulse sequences Sending alarm messages via SMS fax e mail and via data connection or estab...

Страница 14: ...l field strength of 20 AT SIGNAL The current consumption and therefore the power consumption may increase during poor network conditions These are average values for estimating the current consumption...

Страница 15: ...provider The SIM card is the identification towards the network provider The slot for the SIM card is on the front of the INSYS GSM Notes Only 3V cards may be used Changing the SIM card is only permi...

Страница 16: ...ector can be used as antennas Ensure that the frequency band corresponds with the one of the provider when using single band antennas 900 MHz or 1800 MHz 2 5 7 Digital inputs and outputs Alarm input T...

Страница 17: ...60 VDC 1 2 4 5 6 7 8 9 10 3 Power supply IN 1 IN 2 Ext Reset Input 1 GND RESET GND GND 10 60 VDC Input 2 GND Ant INSYS GSM 4 2 INSYS GSM 4 2 compact Bottom Terminal 11 OUT 1 NC Output 1 normally close...

Страница 18: ...0 C to 55 C 2 7 Certifications The INSYS GSM bears the CE symbol of conformity This symbol is a declaration that be cause of its design and implementation the INSYS GSM complies with the currently va...

Страница 19: ...Processing of alarms Dispatch of periodic alive SMS SMS poll ing and power up SMS Connect only IN SYS GSM 4 2 DCD only IN SYS GSM 4 2 compact Yel low Data connection established No data connec tion es...

Страница 20: ...itial state This process takes approximately 30 sec onds The LED Status blinks during this period This corresponds to the command AT RESET Procedure Load factory settings 1 Press the reset key more th...

Страница 21: ...ad at our website http www insys tec de Contact your supplier if the content is not complete Optional accessories GSM antenna outside mounted antenna patch antenna or magnetic base an tenna CD with co...

Страница 22: ...e Device on and Test it 1 Connect the INSYS GSM and the PC using the serial cable 2 Connect the GSM antenna 3 Connect the power supply at the terminals 10 60 VDC and GND Caution Damage of components T...

Страница 23: ...ram Suitable terminal programs TeraTerm HyperTerminal or the HSComm terminal window 3 5 1 Initial configuration via HSComm GSM Warning The AT command sets of the current INSYS GSM and the prior versio...

Страница 24: ...Initial Operation INSYS GSM 4 2 INSYS GSM 4 2 compact 24 Sep 06 1 Start the program HSComm under Windows The configuration software is started and displays the tab Basic settings...

Страница 25: ...settings enter the PIN of the SIM card in the group GSM connec tions in the entry field New pin The PIN is stored in the INSYS GSM and is used for logging into the GSM network at every restart 6 Send...

Страница 26: ...AT BAUD 19200 AT FORMAT 8N1 3 If the INSYS GSM is in an undefined state reset it optionally to the factory settings first AT F WZ AT DEFAULT 4 Enter the PIN Example Entering the PIN 1234 AT PIN 1234...

Страница 27: ...ttempts Notes Only 3V cards may be used Changing the SIM card is only permitted when the device is switched off The slot for the SIM card is on the front of the INSYS GSM Unlocking the card reader Exa...

Страница 28: ...th of the GSM signal 3 7 Connection Test After this successful initial configuration you can easily check whether your INSYS GSM is connected with the GSM network Dial the number of a phone connection...

Страница 29: ...ctory settings by pressing the reset key for a prolonged period Note If possible use the serial interface directly Problems during data transmission may occur when USB serial converters are used No co...

Страница 30: ...value 99 means that the field strength can not be ascertained This occurs during network loss or if an antenna is damaged for example The signal quality is indicated with an update interval of 1 minut...

Страница 31: ...required enter the Pin see Chap 3 5 1 or the PUK see Chap 0 Checking the PIN using an AT command 1 Enter the command AT CPIN in the terminal program The following responses are possible READY No inpu...

Страница 32: ...nse from AT CREG 0 GSM Not logged in Not logged in no GSM network search 1 GSM Logged in Logged in at the standard provider 2 GSM Network search Not registered GSM network search 3 GSM Rejected Reject...

Страница 33: ...using the escape sequence Via the data connection into remote configuration mode using the escape se quence Note The escape sequence activates the command mode Example for the design of a connection a...

Страница 34: ...T commands 4 2 2 Online command mode local During a data connection you can put the INSYS GSM into online command mode by entering the escape sequence via the serial interface Requirements The data co...

Страница 35: ...If it has been set the remote configuration password is queried before changing to the remote configuration mode 4 2 4 SMS configuration You can also send the extended INSYS AT commands to the INSYS...

Страница 36: ...another Operating Mode Activate remote configuration mode Activate online command mode ATD Establish a connection ATH Terminate connection AT EXIT Exit remote configuration mode ATO Exit online comman...

Страница 37: ...iguration software HSComm can be downloaded at http www insys tec de Warning The AT command sets of the current INSYS GSM and the prior version INSYS GSM 2 0 are not identical Use HSComm GSM version 4...

Страница 38: ...which are de scribed with their mode of operation in the current chapter The according chapters of Functions and their configuration will show how to configure the individual functions 5 2 1 Menus The...

Страница 39: ...it is connected The device is immediately read out The button Read values need not be activated Advanced logging Acticate Advanced logging to create a log if errors occur during the configuration You...

Страница 40: ...er several screen pages You may save the overview as text file Note Have the overview available when you call the hotline Send receive log See advanced logging at the menu item Program settings 5 2 2...

Страница 41: ...d the device will immediately afterwards log into the GSM network Synchronize RS232 The serial interfaces of the INSYS GSM and the configuration must be configured equally Use the button Synchronize R...

Страница 42: ...which are de scribed with their mode of operation in the current chapter The according chapters of Functions and their configuration will show how to configure the individual functions 5 3 1 Menus The...

Страница 43: ...it is connected The device is immediately read out The button Read values need not be activated Advanced logging Acticate Advanced logging to create a log if errors occur during the configuration You...

Страница 44: ...er several screen pages You may save the overview as text file Note Have the overview available when you call the hotline Send receive log See advanced logging at the menu item Program settings 5 3 2...

Страница 45: ...d the device will immediately afterwards log into the GSM network Synchronize RS232 The serial interfaces of the INSYS GSM and the configuration must be configured equally Use the button Synchronize R...

Страница 46: ...ave the SIM card PIN in the INSYS GSM The INSYS GSM will automatically dial into the GSM network during startup The default PIN setting is 0000 To operate SIM cards without PIN you may delete the PIN...

Страница 47: ...s the tab Basic settings 2 In the group GSM connection activate the control box New PIN and enter the new PIN in the entry field Note The PIN is encrypted The displayed character is 3 To delete the PI...

Страница 48: ...Corresponding keys OK low short high short ERROR low long 1 Input inactive HIGH high medium long D Input activated LOW low medium long 1 The following extended responses are displayed instead of RING...

Страница 49: ...omm enter the requested number in the tab Basic settings in the group GSM connections in the entry field Di aling attempts Pertinent AT commands AT DIAL Dial up attempts for periodic alive or alarm me...

Страница 50: ...gin It is useful to log the INSYS GSM out for a short period and log in again every day to allow maintenance functions of the GSM provider Enter the logout time and the duration 1 to 98 minutes Subseq...

Страница 51: ...enable scheduled login logout activate one of the check boxes Periodical log out with reset or Periodical logout in the group System monitoring and enter the requested values in the entry fields Time...

Страница 52: ...e Select the requested values in the fields Baud rate and Data format Note The interface parameters of the configuration PC must match the interface pa rameters of the INSYS GSM Set the serial interfa...

Страница 53: ...serial interface The INSYS GSM is operated at a device which does not sup port hardware handshake No handshake The INSYS GSM ignores redundant data Software handshake The INSYS GSM controls the data f...

Страница 54: ...The INSYS GSM is operated at a device which does not sup port hardware handshake No DTR behavior The INSYS GSM does not utilize the DTR signal Hanging up The INSYS GSM terminates the connection if the...

Страница 55: ...SRX Automatic SMS reception processing 6 2 2 Receiving SMS SMS are stored at the SMS storage locations in the SIM card You can read out the num ber of all available SMS storage locations on the SIM ca...

Страница 56: ...e if necessary and deletes it from the SMS memory SMS usable by the INSYS GSM All SMS messages with a correct configuration password All SMS messages with correct syntax and no configuration password...

Страница 57: ...Comm set a check mark in the check box Automatic SMS processing in the tab Basic settings in the group GSM con nection Pertinent AT commands AT SMSRX Automatic SMS reception processing 6 2 4 Commands...

Страница 58: ...he following cases the handshake of the serial interface see Chap 6 1 9 and the DTR behavior see Chap 6 1 10 must be deacti vated The INSYS GSM is operated as a stand alone device i e it is not connec...

Страница 59: ...Functions and their Configuration Sep 06 59 AT CMGS Send SMS message AT CSCA Number of the SMS service center AT SMGL List SMS messages without changing the status AT SMGO SMS overflow AT SMGR Read SM...

Страница 60: ...ect the following settings Meaning Parameters SMS service center 491710760000 Phone number 990123456789 Message 140 text characters max Message 2 In order to transmit a message via SMS from the Vodafo...

Страница 61: ...o the GSM network at cops Response logged into T Mobile D COPS 0 0 T Mobile D OK Service Center Number at csca Response has already been en tered CSCA 491710760000 145 OK Set SMS text mode at cmgf 1 O...

Страница 62: ...ia AT commands SMS or DTMF AT command Enter the command AT IN via a terminal program or the HSComm terminal window The AT command will send the following response OPEN Not activated open CLOSE Activat...

Страница 63: ...se alarm Sequences of up to 10 pulses can be detected as different alarms at the pulse input Pulses and pauses may last from 0 3 to 2 seconds You can assign each pulse alarm a message with the followi...

Страница 64: ...es The alarm input is no longer active Via the idle detection If the remote terminal hangs up DTR drop AT command ATH 9 Establishing a Short data connection The data connection is immediately terminat...

Страница 65: ...SM sends an alarm message via SMS or data connection or establishes a voice connection it will disconnect an existing data connection The INSYS GSM ignores incoming commands during the processing of t...

Страница 66: ...ons Therefore the following restrictions must be observed for SMS texts Never use the character 0x00h Permitted text characters in SMS messages are only letters without umlauts digits punctuation mark...

Страница 67: ...pulse alarm also enter the collective message text in the field Collective message text 5 Enter the according recipient number in the field Recipient number 6 If you need to set the according switch...

Страница 68: ...3228 491606749832 491727895431 The pulse alarm message 2 of the alarm input 1 is sent to the specified numbers as well 491731223228 The pulse alarm messages 2 3 4 5 8 and 9 of the alarm input 1 are se...

Страница 69: ...rm messages AT DIAL Dial up attempts for periodic alive or alarm messages AT SCN SMS service center number AT COMBINE Combination of the alarm text with a target number from the number pool AT POOL Ph...

Страница 70: ...are available Activate by waiting alarm at relevant alarm input The INSYS GSM can signal to an external device that the alarm input is busy Activate for the duration of an incoming RING signal An inco...

Страница 71: ...Meaning Parameters Possible values Meaning Default 1 Switch output 1 Switch output for which the setting shall be valid output 2 Switch output 2 1 0 Not released Manual switching with command AT OUT...

Страница 72: ...1 AT OUT output status Meaning Parameters Possible values Meaning Default 1 Switch output 1 Switch output for which the setting shall be valid output 2 Switch output 2 1 0 Switch output on normally o...

Страница 73: ...ion Sep 06 73 6 5 Access Control You can protect the INSYS GSM from unauthorized access The following options are available Selective Call Answer Passwords and DTMF PIN Security callback You can confi...

Страница 74: ...for a call with CLIP without The transmitted format of the number may depend on the provider e g the leading 49 may be replaced by 0049 Note We urgently recommend verifying the number by placing a tes...

Страница 75: ...enter the password after 2 seconds If no valid password is entered within 60 seconds the INSYS GSM will terminate the con nection A valid password is acknowledged with OK If no security callback numbe...

Страница 76: ...ack The security callback process 1 If a security callback number was entered the INSYS GSM will query the password for all connections and terminate the connection 2 If the password was correct the I...

Страница 77: ...rom the INSYS GSM are not affected Procedure Activate security callback 1 Start the HSComm and switch to the tab Access control 2 Enter the requested number in the group Callback number Pertinent AT c...

Страница 78: ...ntries Reason Detail Meaning RTC ERROR Internal real time clock is faulty time stamp empty RTC RESET The internal real time clock has been reset as the gold cap was dis charged power reserve used up T...

Страница 79: ...ce connection terminated Start Data connection outgoing or incoming Incoming number only for activated selected call acceptance DATA End Data connection terminated Power up Power up SMS was sent PARAM...

Страница 80: ...8 Flash update You can update the INSYS GSM firmware locally or via a data connection The firmware is available as MHX file from the technical support department Call technical support at E mail insys...

Страница 81: ...h a timeout of 2 seconds Start Update with Esc Reset with Prompt for sending Send the firmware as MHX file Expecting download with 8N1 Required settings of the terminal program Log ASCII Data format 8...

Страница 82: ...the remote device Depending on which PLC you are connecting you must initialize the INSYS GSM or the modem accordingly For setting the PLC data two modem settings are available Configure PC modem When...

Страница 83: ...HX CPU44 PILZ SPS PSS3056 Schiele SPS S400 Siemens S7 200 Systron S200 S250 and S400 Note You can adjust the default settings for the initialization and com munication strings Changes will not be save...

Страница 84: ...SMS is restricted to commands with responses of up to 140 characters The most important standard AT commands and all extended AT commands are listed in the document AT Command Set for INSYS GSM 4 2 wh...

Страница 85: ...target number for alarm messages X X S AT DTC Idle connection control Data Transmit Controller X X X AT DTMF Enable DTMF processing X X X AT ESC Escape character for remote command mode X X X AT EXIT...

Страница 86: ...DER Manual GSM provider selection X X X AT RESET Device reset X X X AT SCN SMS service center number X X X AT SIGNAL GSM signal field strength X X X AT SMS Manual SMS dispatch of the stored alarm mess...

Страница 87: ...le locally via command ITAS AT OUTPUT AT SMSRX Automatic SMS reception processing has to be enabled with AT SMSRX ITB AT BAUD Common baud rate for controller and GSM engine ITD AT DST ITDC AT CALLBACK...

Страница 88: ...Center Number SCN Fax Prefix Number of the E mail gateway D T Mobile T D1 49 171 076 0000 49 171 209 2522 99 German 98 English 8000 D Vodafone D2 D2 Vodafone 49 172 227 0000 49 172 227 0042 49 172 22...

Страница 89: ......

Отзывы: