Overview S Registry
Register Function
Units Range Default
S0*
Rings to auto answer
rings
0-5
5
S1 Ring
counter
rings
0-255 0
S2* Escape
character
ASCII
0-255 43
S3 Return
character
ASCII
0-127
13
S4 Line
feed
character
ASCII
0-127
10
S5 Backspace
character
ASCII
0-255 8
S6*
Waiting time for dial tone
s
3-7
3
S7*
Waiting time for carrier signal
s
0-100
50
S8* Dialing
pause
s
1-7 2
S9*
Reaction time on carrier signal
0.1 s
1-255
6
S10*
Time between lost carrier signal and hang-up
0.1 s
14-254
14
S12*
ESC prompt delay
0.02 s
0-255 50
S13*
Number of dialing attempts for alarm
1-12
3
S14* General
settings
146
S15*
Data Transmit Controller DTC
1s
0-255
0
S17*
Remote initial character
0-127
42
S21*
Settings for V24
52
S22* Settings
117
S24*
Time until changing to sleep mode
s
0-255
0
S25
Time for DTR signal
0.01 s
0-255 5
S26
Time between RTS/CTS
0.01 s
0-255 1
S27* General
settings
-
137
S29
Time for modifiers „flash“
10 ms
0-17 17
76