2634-222 - Rev: 2/11/2019 9:16 AM 

Screw On/Off Outdoor Module 
connections 

None 

Case color  

Dark gray 

Set button 

Yes 

Plastic 

UV stabilized polycarbonate 

Beeper 

Yes 

LED 

1, Red-Green 

Dimensions 

2.75"W x 4.32"H x 1.27"D (with 6" lead) 

70mm W x 110mm H x 32mm D (with 150mm lead) 

Weight 

.465lbs (7.2 oz) .21kg 

Operating environment 

Indoor/outdoor 

Rainproof rated 

NEMA Type 3R Enclosure 

Operating temperature range 

-4° to 122° F  

-20° to 50° C 

Storage temperature range 

-4

o

 to 158

o

 F  

-20

o

 to 70

o

 C 

Operating humidity range 

0 - 90% relative humidity 

Electrical 

Voltage 

120 Volts AC +/- 10% 

Frequency 

60Hz  

Load type(s) 

Standard appliances up to 12 Amps and incandescent lights up 
to 1440 watts 

Maximum load 

12 Amps; 1440 Watts (for incandescent loads) 

Minimum load 

None 

User replaceable fuse 

None 

Retains all settings without power 

Yes, saved in non-volatile EEPROM 

Standby power consumption 

< 1 watt 

Safety approval(s) 

Conforms to ANSI/UL Std. 508-2005 

Certified to CAN/CSA Std. C22.2 #14-05 

FCC ID 

SBP26342 

 

 
 

 
 

 
 

 
 

 
 

 
 

 

Содержание 2634-222

Страница 1: ...Page 1 of 13 2634 222 Rev 2 11 2019 9 16 AM On Off Outdoor Module Owner s Manual 2634 222...

Страница 2: ...rollers Responders and Links 6 Make On Off Outdoor Module a Responder 6 Make On Off Outdoor Module a Controller 6 Groups 7 Scenes 7 Remove On Off Outdoor Module as a Responder 7 Remove On Off Outdoor...

Страница 3: ...s and links to other INSTEON devices in minutes Controls standard incandescent loads up to 1440 Watts and inductive loads up to 12 Amps Weatherproof to withstand harsh outdoor conditions Indicates INS...

Страница 4: ...GFCI device Don t bury On Off Outdoor Module any electrical cable or component connected to it A buried power cord may result in electrocution if improper cables are used or if digging occurs over the...

Страница 5: ...ntroller On Off Outdoor Module LED will blink green for INSTEON traffic and if it detects noise that could disrupt communication Programming Lock Default disabled This setting is only adjustable via s...

Страница 6: ...ad to desired state on or off 3 Press and hold On Off Outdoor Module set button until it double beeps Controller will double beep and its LED will stop blinking 4 Test link by tapping controller butto...

Страница 7: ...as a member 1 Press and hold controller set button until it beeps Controller LED will start blinking green 2 Tap controller set button Controller LED will start double blinking green 3 Use On Off Modu...

Страница 8: ...ing is disabled on On Off Outdoor Module by default but you can enable it by following these steps Enable Load Sensing 1 Press and hold On Off Outdoor Module set button until it beeps 3 seconds On Off...

Страница 9: ...400 LED Green when load is on red when load is off Blinks red or green during setup Beep on button press No Local control Yes Commands supported as controller On Off Commands supported as responder On...

Страница 10: ...ng temperature range 4 to 122 F 20 to 50 C Storage temperature range 4 o to 158 o F 20 o to 70 o C Operating humidity range 0 90 relative humidity Electrical Voltage 120 Volts AC 10 Frequency 60Hz Loa...

Страница 11: ...to a controller The controller may be sending commands to a responder that is no longer in use Commands for the unused responder are being resent and loading down the signal Unlink any unused responde...

Страница 12: ...evice does not provide a phase bridge to Micro module Relocate if necessary and practical If the other dual band device is not blinking Device is not within RF range of Micro module so it does not pro...

Страница 13: ...lament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente...